Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors
- PMID: 2184569
- DOI: 10.1177/016173469001200105
Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors
Abstract
In previous work, we demonstrated that accurate backscatter coefficient measurements are obtained with a data reduction method that explicitly accounts for experimental factors involved in recording echo data. An alternative, relative processing method for determining the backscatter coefficient and the attenuation coefficient is presented here. This method involves comparison of echo data from a sample with data recorded from a reference phantom whose backscatter and attenuation coefficients are known. A time domain processing technique is used to extract depth and frequency dependent signal ratios for the sample and the reference phantom. The attenuation coefficient and backscatter coefficient of the sample are found from these ratios. The method is tested using tissue-mimicking phantoms with known scattering and attenuation properties.
Similar articles
-
Statistical uncertainty in ultrasonic backscatter and attenuation coefficients determined with a reference phantom.Ultrasound Med Biol. 1991;17(2):187-94. doi: 10.1016/0301-5629(91)90126-h. Ultrasound Med Biol. 1991. PMID: 2053215
-
Instrument-independent acoustic backscatter coefficient imaging.Ultrason Imaging. 1988 Apr;10(2):121-38. doi: 10.1177/016173468801000204. Ultrason Imaging. 1988. PMID: 3057712
-
Comparison of ultrasound attenuation and backscatter estimates in layered tissue-mimicking phantoms among three clinical scanners.Ultrason Imaging. 2012 Oct;34(4):209-21. doi: 10.1177/0161734612464451. Ultrason Imaging. 2012. PMID: 23160474 Free PMC article.
-
Simultaneous backscatter and attenuation estimation using a least squares method with constraints.Ultrasound Med Biol. 2011 Dec;37(12):2096-104. doi: 10.1016/j.ultrasmedbio.2011.08.008. Epub 2011 Oct 2. Ultrasound Med Biol. 2011. PMID: 21963038 Free PMC article.
-
[Quantitative backscatter imaging].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1999 Mar;16(1):96-9. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1999. PMID: 12553286 Review. Chinese.
Cited by
-
Ultrasound Attenuation Estimation in Harmonic Imaging for Robust Fatty Liver Detection.Ultrasound Med Biol. 2020 Nov;46(11):3080-3087. doi: 10.1016/j.ultrasmedbio.2020.07.006. Epub 2020 Aug 6. Ultrasound Med Biol. 2020. PMID: 32773254 Free PMC article.
-
Artificial Intelligence-Enhanced Quantitative Ultrasound for Breast Cancer: Pilot Study on Quantitative Parameters and Biopsy Outcomes.Diagnostics (Basel). 2024 Feb 14;14(4):419. doi: 10.3390/diagnostics14040419. Diagnostics (Basel). 2024. PMID: 38396457 Free PMC article.
-
Evaluation of ultrasonic scattering in agar-based phantoms using 3D printed scattering molds.J Ultrasound. 2022 Sep;25(3):597-609. doi: 10.1007/s40477-021-00630-7. Epub 2022 Jan 8. J Ultrasound. 2022. PMID: 34997563 Free PMC article.
-
Platform for quantitative multiscale imaging of tissue composition.Biomed Opt Express. 2020 Mar 12;11(4):1927-1946. doi: 10.1364/BOE.383248. eCollection 2020 Apr 1. Biomed Opt Express. 2020. PMID: 32341858 Free PMC article.
-
Quantitative ultrasound approaches for diagnosis and monitoring hepatic steatosis in nonalcoholic fatty liver disease.Theranostics. 2020 Mar 4;10(9):4277-4289. doi: 10.7150/thno.40249. eCollection 2020. Theranostics. 2020. PMID: 32226553 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources