Intersession reliability of the electromyographic signal during incremental cycle ergometry: quadriceps femoris
- PMID: 22102465
- DOI: 10.1002/mus.22211
Intersession reliability of the electromyographic signal during incremental cycle ergometry: quadriceps femoris
Abstract
Introduction: The purposes of this investigation were to determine the: (1) reproducibility of the patterns of responses for electromyographic (EMG) amplitude and mean power frequency (MPF); and (2) intraclass correlation coefficient (ICC) of the EMG amplitude and MPF during three incremental cycle ergometer tests separated by 48 hours.
Methods: Ten men performed incremental cycle ergometry tests to exhaustion on three separate occasions. Surface EMG signals were recorded simultaneously from the three superficial quadriceps muscles at each trial.
Results: Polynomial regression indicated that, for >95% of the cases, the best-fit model was the same at each trial for EMG amplitude but not for EMG MPF. The ICC values were high for EMG amplitude but low for EMG MPF.
Conclusions: These results indicate that EMG amplitude is a reliable measure of motor unit activation strategy during incremental cycle ergometry, whereas the EMG MPF was unreliable.
Copyright © 2011 Wiley Periodicals, Inc.
Similar articles
-
The effects of innervation zone on electromyographic amplitude and mean power frequency during incremental cycle ergometry.J Neurosci Methods. 2006 Jul 15;155(1):126-33. doi: 10.1016/j.jneumeth.2006.01.019. Epub 2006 Feb 28. J Neurosci Methods. 2006. PMID: 16510193
-
Comparison of electromyographic responses for the superficial quadriceps muscles: cycle versus knee-extensor ergometry.Muscle Nerve. 2009 Jun;39(6):810-8. doi: 10.1002/mus.21295. Muscle Nerve. 2009. PMID: 19301365
-
The effects of interelectrode distance on electromyographic amplitude and mean power frequency during incremental cycle ergometry.J Neurosci Methods. 2006 Mar 15;151(2):139-47. doi: 10.1016/j.jneumeth.2005.06.025. Epub 2005 Aug 24. J Neurosci Methods. 2006. PMID: 16122806 Clinical Trial.
-
The effects of electrode orientation on electromyographic amplitude and mean power frequency during cycle ergometry.J Neurosci Methods. 2009 Nov 15;184(2):256-62. doi: 10.1016/j.jneumeth.2009.08.008. Epub 2009 Aug 19. J Neurosci Methods. 2009. PMID: 19698747
-
The relationship between electromyography and work intensity revisited: a brief review with references to lacticacidosis and hyperammonia.Electromyogr Clin Neurophysiol. 1997 Oct;37(7):387-98. Electromyogr Clin Neurophysiol. 1997. PMID: 9402427 Review.
Cited by
-
The repeatability of neuromuscular activation strategies recorded in recreationally active individuals during cycling.Eur J Appl Physiol. 2022 Apr;122(4):1045-1057. doi: 10.1007/s00421-022-04899-2. Epub 2022 Feb 15. Eur J Appl Physiol. 2022. PMID: 35166903 Free PMC article.
-
Do Young People Ever Sit Still? Variations in Accelerometer Counts, Muscle Activity and Heart Rate across Various Sedentary Activities in Youth.Int J Environ Res Public Health. 2018 May 17;15(5):1009. doi: 10.3390/ijerph15051009. Int J Environ Res Public Health. 2018. PMID: 29772819 Free PMC article.
-
Inter-individual variability in the patterns of responses for electromyography and mechanomyography during cycle ergometry using an RPE-clamp model.Eur J Appl Physiol. 2016 Sep;116(9):1639-49. doi: 10.1007/s00421-016-3394-y. Epub 2016 Jun 20. Eur J Appl Physiol. 2016. PMID: 27325528
-
Impact of Power Output on Muscle Activation and 3D Kinematics During an Incremental Test to Exhaustion in Professional Cyclists.Front Sports Act Living. 2021 Mar 10;2:516911. doi: 10.3389/fspor.2020.516911. eCollection 2020. Front Sports Act Living. 2021. PMID: 33778484 Free PMC article.
-
Evaluation of Electromyographic Frequency Domain Changes during a Three-Minute Maximal Effort Cycling Test.J Sports Sci Med. 2015 May 8;14(2):452-8. eCollection 2015 Jun. J Sports Sci Med. 2015. PMID: 25983596 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous