Predicting detection limits of enzyme-linked immunosorbent assay (ELISA) and bioanalytical techniques in general
- PMID: 24308031
- DOI: 10.1039/c3an01835k
Predicting detection limits of enzyme-linked immunosorbent assay (ELISA) and bioanalytical techniques in general
Abstract
The detection limit is one of the most important performance parameters for bioanalytical techniques. Here we present a generic method to estimate the detection limit of biomolecular assays based on a step-by-step analysis of the assay procedure. Enzyme-linked immunosorbent assay (ELISA) is used here as an example; however, much of the information presented in this article may be applied to other types of biomolecular assays and analytical techniques. A clear understanding of what affects the detection limit can help researchers to evaluate different bio-analytical techniques properly, and to design better strategies to optimize and achieve the best analytical performance.
Similar articles
-
Tandem conjugation of enzyme and antibody on silica nanoparticle for enzyme immunoassay.Anal Biochem. 2010 Nov 1;406(1):8-13. doi: 10.1016/j.ab.2010.06.039. Epub 2010 Jul 1. Anal Biochem. 2010. PMID: 20599640
-
Advantages of soybean peroxidase over horseradish peroxidase as the enzyme label in chemiluminescent enzyme-linked immunosorbent assay of sulfamethoxypyridazine.J Agric Food Chem. 2010 Mar 24;58(6):3284-9. doi: 10.1021/jf904338f. J Agric Food Chem. 2010. PMID: 20175541
-
Optofluidic laser for dual-mode sensitive biomolecular detection with a large dynamic range.Nat Commun. 2014 Apr 30;5:3779. doi: 10.1038/ncomms4779. Nat Commun. 2014. PMID: 24781061
-
Low-cost and easy-to-use "on-chip ELISA" for developing health-promoting foods.Subcell Biochem. 2014;77:151-61. doi: 10.1007/978-94-007-7920-4_13. Subcell Biochem. 2014. PMID: 24374926 Review.
-
[Method for estimating the precision and detection limit for ELISA].Nihon Yakurigaku Zasshi. 2009 Oct;134(4):207-11. doi: 10.1254/fpj.134.207. Nihon Yakurigaku Zasshi. 2009. PMID: 19828925 Review. Japanese. No abstract available.
Cited by
-
Critical Offset Magnetic PArticle SpectroScopy for rapid and highly sensitive medical point-of-care diagnostics.Nat Commun. 2022 Nov 24;13(1):7230. doi: 10.1038/s41467-022-34941-y. Nat Commun. 2022. PMID: 36433976 Free PMC article.
-
A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers.Sci Rep. 2016 Jul 26;6:30474. doi: 10.1038/srep30474. Sci Rep. 2016. PMID: 27456979 Free PMC article.
-
Screen-Printed Electrodes (SPE) for In Vitro Diagnostic Purpose.Diagnostics (Basel). 2020 Jul 26;10(8):517. doi: 10.3390/diagnostics10080517. Diagnostics (Basel). 2020. PMID: 32722552 Free PMC article. Review.
-
Transmissive Nanohole Arrays for Massively-Parallel Optical Biosensing.ACS Photonics. 2014 Mar 19;1(3):241-245. doi: 10.1021/ph400111u. Epub 2014 Feb 6. ACS Photonics. 2014. PMID: 25530982 Free PMC article.
-
Spatiotemporal dissection of tumor microenvironment via in situ sensing and monitoring in tumor-on-a-chip.Biosens Bioelectron. 2023 Apr 1;225:115064. doi: 10.1016/j.bios.2023.115064. Epub 2023 Jan 5. Biosens Bioelectron. 2023. PMID: 36680970 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources