{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T07:54:40Z","timestamp":1725868480924},"publisher-location":"Cham","reference-count":12,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783319483344"},{"type":"electronic","value":"9783319483351"}],"license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016]]},"DOI":"10.1007\/978-3-319-48335-1_13","type":"book-chapter","created":{"date-parts":[[2016,10,14]],"date-time":"2016-10-14T15:17:09Z","timestamp":1476458229000},"page":"119-128","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A Novel Indicator for Cuff-Less Blood Pressure Estimation Based on Photoplethysmography"],"prefix":"10.1007","author":[{"given":"Hongyang","family":"Jiang","sequence":"first","affiliation":[]},{"given":"Fen","family":"Miao","sequence":"additional","affiliation":[]},{"given":"Mengdi","family":"Gao","sequence":"additional","affiliation":[]},{"given":"Xi","family":"Hong","sequence":"additional","affiliation":[]},{"given":"Qingyun","family":"He","sequence":"additional","affiliation":[]},{"given":"He","family":"Ma","sequence":"additional","affiliation":[]},{"given":"Ye","family":"Li","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2016,10,15]]},"reference":[{"key":"13_CR1","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/S0002-9149(99)00635-9","volume":"85","author":"WB Kannel","year":"2000","unstructured":"Kannel, W.B.: Elevated systolic blood pressure as a cardiovascular risk factor. Am. J. Cardiol. 85, 251\u2013255 (2000)","journal-title":"Am. J. Cardiol."},{"key":"13_CR2","doi-asserted-by":"publisher","first-page":"1879","DOI":"10.1109\/TBME.2015.2441951","volume":"62","author":"R Mukkamala","year":"2015","unstructured":"Mukkamala, R., Hahn, J.O., Inan, O.T., Mestha, L.K., Kim, C.S., Toreyin, H., Kyal, S.: Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice. IEEE Trans. Biomed. Eng. 62, 1879\u20131901 (2015)","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"13_CR3","doi-asserted-by":"crossref","unstructured":"Kachuee, M., Kiani, M.M., Mohammadzade, H., Shabany, M.: Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. In: IEEE International Symposium on Circuits and Systems, pp. 1006\u20131009 (2015)","DOI":"10.1109\/ISCAS.2015.7168806"},{"key":"13_CR4","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1007\/s00421-011-1983-3","volume":"112","author":"H Gesche","year":"2012","unstructured":"Gesche, H., Grosskurth, D., K\u00fcchler, G., Patzak, A.: Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method. Eur. J. Appl. Physiol. 112, 309\u2013315 (2012)","journal-title":"Eur. J. Appl. Physiol."},{"key":"13_CR5","doi-asserted-by":"crossref","unstructured":"Suzuki, S., Oguri, K.: Cuff-less and non-invasive systolic blood pressure estimation for aged class by using a photoplethysmograph. In: 30th IEEE International Conference Engineering on Medicine and Biology Society, Vancouver, British Columbia, Canada, pp. 1327\u20131330 (2008)","DOI":"10.1109\/IEMBS.2008.4649409"},{"key":"13_CR6","doi-asserted-by":"crossref","unstructured":"Fukushima, H., Kawanaka, H., Bhuiyan, M.S., Oguri, K.: Cuff-less blood pressure estimation using only photoplethysmography based on cardiovascular parameters. In: 35th IEEE International Conference Engineering on Medicine and Biology Society, Osaka, Japan, pp. 2132\u20132135 (2013)","DOI":"10.1109\/EMBC.2013.6609955"},{"key":"13_CR7","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1152\/advan.00097.2011","volume":"36","author":"Y Hodgson","year":"2012","unstructured":"Hodgson, Y., Choate, J.: Continuous and noninvasive recording of cardiovascular parameters with the Finapres finger cuff enhances undergraduate student understanding of physiology. Adv. Physiol. Educ. 36, 20\u201326 (2012)","journal-title":"Adv. Physiol. Educ."},{"key":"13_CR8","unstructured":"Song, S.H., Cho, J.S., Oh, H.S., Lee, J.S., Kim, I.Y.: Estimation of blood pressure using photoplethysmography on the wrist. In: Computers in Cardiology, pp. 741\u2013744 (2009)"},{"key":"13_CR9","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1023\/A:1016936206694","volume":"21","author":"H Takada","year":"1995","unstructured":"Takada, H., Washino, K., Harrell, J.S., Iwata, H.: Acceleration plethysmography to evaluate aging effect in cardiovascular system. Using new criteria of four wave patterns. Med. Prog. Technol. 21, 205\u2013210 (1995)","journal-title":"Med. Prog. Technol."},{"key":"13_CR10","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1161\/01.HYP.32.2.365","volume":"32","author":"K Takazawa","year":"1998","unstructured":"Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., Ibukiyama, C.: Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. Hypertension 32, 365\u2013370 (1998)","journal-title":"Hypertension"},{"key":"13_CR11","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1109\/TII.2013.2288498","volume":"10","author":"A Suzuki","year":"2014","unstructured":"Suzuki, A., Ryu, K.: Feature selection method for estimating systolic blood pressure using the Taguchi method. IEEE Trans. Ind. Inform. 10, 1077\u20131085 (2014)","journal-title":"IEEE Trans. Ind. Inform."},{"key":"13_CR12","doi-asserted-by":"crossref","unstructured":"Datta, S., Banerjee, R., Choudhury, A.D., Sinha, A., Pal, A.: Blood pressure estimation from photoplethysmogram using latent parameters. In: IEEE International Conference on Communications, Kuala Lumpur, Malaysia, pp. 1\u20137 (2016)","DOI":"10.1109\/ICC.2016.7511599"}],"container-title":["Lecture Notes in Computer Science","Health Information Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-319-48335-1_13","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,7]],"date-time":"2024-03-07T14:19:11Z","timestamp":1709821151000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-319-48335-1_13"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"ISBN":["9783319483344","9783319483351"],"references-count":12,"URL":"https:\/\/doi.org\/10.1007\/978-3-319-48335-1_13","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2016]]},"assertion":[{"value":"15 October 2016","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"HIS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Health Information Science","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Shanghai","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"China","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2016","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"5 November 2016","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"7 November 2016","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"5","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"his22016","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}