Medical glove

(Redirected from Latex glove)

Medical gloves are disposable gloves used during medical examinations and procedures to help prevent cross-contamination between caregivers and patients.[1] Medical gloves are made of different polymers including latex, nitrile rubber, polyvinyl chloride and neoprene; they come unpowdered, or powdered with corn starch to lubricate the gloves, making them easier to put on the hands.[2]

Dentist wearing nitrile gloves

Corn starch replaced tissue-irritating lycopodium powder and talc, but even corn starch can impede healing if it gets into tissues (as during surgery). As such, unpowdered gloves are used more often during surgery and other sensitive procedures. Special manufacturing processes are used to compensate for the lack of powder.

There are two main types of medical gloves: examination and surgical. Surgical gloves have more precise sizing with a better precision and sensitivity and are made to a higher standard. Examination gloves are available either sterile or non-sterile, while surgical gloves are generally sterile.[3]

Besides medicine, medical gloves are widely used in chemical and biochemical laboratories. Medical gloves offer some basic protection against corrosives and surface contamination. However, they are easily penetrated by solvents and various hazardous chemicals, and should not be used for dishwashing or otherwise when the task involves immersion of the gloved hand in the solvent.[citation needed] Medical gloves are recommended to be worn for two main reasons:[4]

  1. To reduce the risk of contamination of health-care workers hands with blood and other body fluids.
  2. To reduce the risk of germ dissemination to the environment and of transmission from the health-care worker to the patient and vice versa, as well as from one patient to another.

History

edit

Caroline Hampton became the chief nurse of the operating room when Johns Hopkins Hospital opened in 1889.[5] When "in the winter of 1889 or 1890" she developed a skin reaction to mercuric chloride that was used for asepsis, William Halsted, soon-to-be her husband, asked the Goodyear Rubber Company to produce thin rubber gloves for her protection.[5] In 1894 Halsted implemented the use of sterilized medical gloves at Johns Hopkins.[6][7] However, the first modern disposable glove was invented by Ansell Rubber Co. Pty. Ltd. in 1965.[8][9][10]

Glove materials

They based the production on the technique for making condoms.[11] These gloves have a range of clinical uses ranging from dealing with human excrement to dental applications.[citation needed]

Criminals have also been known to wear medical gloves during commission of crimes. These gloves are often chosen because their thinness and tight fit allow for dexterity. However, because of the thinness of these gloves, fingerprints may actually pass through the material as glove prints, thus transferring the wearer's prints onto the surface touched or handled.[12]

The participants of the Watergate burglaries infamously wore rubber surgical gloves in an effort to hide their fingerprints.[13]

Industry

edit

In 2020, the market for medical gloves had a value of more than USD 10.17 billion and, with growing demand (especially in developing countries), is expected to grow by 9.2 per cent per year until 2028.[14] The majority of medical gloves is manufactured in South East Asia with Malaysia alone accounting for about three quarters of global production in 2020.[15]

Labour rights violations

edit

There have been several investigations in factories in Malaysia, Thailand and Sri Lanka that documented severe violations of human and labour rights. Both in Malaysia and Thailand migrants represent the majority of workers in hard physical labour. They are frequently recruited by specialized agencies in their less affluent home countries such as Nepal and are often charged with high recruitment fees forcing them into debt bondage. There are documented cases in which employees' passports were withheld by their employers leaving them especially vulnerable to exploitation.[16][17] In 2010, for instance, Swedwatch, a Swedish labour right NGO examining a Malaysian factory, reported that most employees were working 12 hours per day seven days a week without overtime pay or payslip, harassment of workers by the management, safety deficits and poor hygienic conditions in employee housing.[18] [16] Reacting to these findings, from October 2019 to March 2020, the US Department of Labor listed medical gloves produced in Malaysia on the List of Goods Produced by Child Labor or Forced Labor and temporarily banned the import of gloves produced by the Malaysian company Top Glove, the world's largest manufacturer at the time.[19][20]

Sizing

edit

Generally speaking, examination gloves are sized in XS, S, M and L. Some brands may offer size XL. Surgical gloves are usually sized more precisely since they are worn for a much longer period of time and require exceptional dexterity. The sizing of surgical gloves are based on the measured circumference around the palm (excluding the thumb) in inches, at a level slightly above the thumb's sewn. Typical sizing ranges from 5.5 to 9.0 at an increment of 0.5. Some brands may also offer size 5.0. First-time users of surgical gloves may take some time to find the right size and brand that suit their hand geometry the most.[21] People with a thicker palm may need a size larger than the measurement and vice versa. Sizing should be one of the first thing to look for. Dexterity is essential for every worker and wearing the wrong size of glove can have a huge impact on someone's work. Wearing the right size of glove can also increase comfort, which can influence workers to wear their assigned PPE.[22]

Research on a group of American surgeons found that the most common surgical glove size for men is 7.0, followed by 6.5; and for women 6.0 followed by 5.5.[23]

Powdered gloves

edit

To facilitate donning of gloves, powders have been used as lubricants. Early powders derived from pines or club moss were found to be toxic.[24] Talcum powder was used for decades but linked to postoperative granuloma and scar formation. Corn starch, another agent used as lubricant, was also found to have potential side effects such as inflammatory reactions and granuloma and scar formation.[24][25]

Elimination of powdered medical gloves

edit

With the availability of non-powdered medical gloves that were easy to don, calls for the elimination of powdered gloves became louder. By 2016, healthcare systems in Germany and the United Kingdom had eliminated their use.[24] In March 2016, the United States Food and Drug Administration (FDA) issued a proposal to ban their medical use[26] and on December 19, 2016 passed a rule banning all powdered gloves intended for medical use.[27] The rule became effective on January 18, 2017.[28]

Powder-free medical gloves are used in medical cleanroom environments, where the need for cleanliness is often similar to that in a sensitive medical environment.[29]

Chlorination

edit

To make them easier to don without the use of powder, gloves can be treated with chlorine. Chlorination affects some of the beneficial properties of latex, but also reduces[30] the quantity of allergenic latex proteins.[31]

Polymer coating

edit

On the market, it is a wide range of applications for polymer coatings in the market. Most of the current disposable gloves are powdered. These coatings include several polymers: silicone, acrylic resins, and gels that make gloves easier to wear. This process is currently used in nitrile gloves and latex gloves.[32]

Alternatives to latex

edit
 
Nitrile powder free gloves

Due to the increasing rate of latex allergy among health professionals,[33] and in the general population, gloves made of non-latex materials such as polyvinyl chloride, nitrile rubber, or neoprene have become widely used. Chemical processes may be employed to reduce the amount of antigenic protein in Hevea latex, resulting in alternative natural-rubber-based materials such Vytex Natural Rubber Latex. However, non-latex gloves have not yet replaced latex gloves in surgical procedures, as gloves made of alternative materials generally do not fully match the fine control or greater sensitivity to touch available with latex surgical gloves.[citation needed] (High-grade isoprene gloves are the only exception to this rule, as they have the same chemical structure as natural latex rubber. However, fully artificial polyisoprene—rather than "hypoallergenic" cleaned natural latex rubber[34]—is also the most expensive natural latex substitute available.[35]) Other high-grade non-latex gloves, such as nitrile gloves, can cost over twice the price of their latex counterparts, a fact that has often prevented switching to these alternative materials in cost-sensitive environments, such as many hospitals.[citation needed] Nitrile is more resistant to tearing than natural latex, and is more resistant to many chemicals.[36] Sulfur compounds used as accelerants to cure nitrile can speed the tarnishing process in silver, so accelerant-free nitrile or other gloves must be used when handling objects made of these metals when this is not acceptable.[36]

Double gloving

edit

Double gloving is the practice of wearing two layers of medical gloves to reduce the danger of infection from glove failure or penetration of the gloves by sharp objects during medical procedures. Surgeons double glove when operating on individuals bearing infectious agents such as HIV and hepatitis, and to better protect patients against infections possibly transmitted by the surgeon. A systematic review of the literature has shown double gloving to offer significantly more protection against inner glove perforation in surgical procedures compared to the use of a single glove layer. But it was unclear if there was better protection against infections transmitted by the surgeon.[37] Another systematic review studied if double gloving protected the surgeon better against infections transmitted by the patient. Pooled results of 12 studies (RCTs) with 3,437 participants showed that double gloving reduced the number of perforations in inner gloves with 71% compared to single gloving. On average ten surgeons/nurses involved in 100 operations sustain 172 single gloves perforations but with double gloves only 50 inner gloves would be perforated. This is a considerable reduction of the risk.[38]

In addition, cotton gloves can be worn under the single-use gloves to reduce the amount of sweat produced when wearing these gloves for a long period of time. These under gloves can be disinfected and used again.[39]

See also

edit

References

edit
  1. ^ "Medical Gloves and Gowns". FDA. Archived from the original on 2009-05-13. Retrieved 2010-03-10.   One or more of the preceding sentences incorporates text from this source, which is in the public domain.
  2. ^ "Glove manufacturing". Ansell.eu. Archived from the original on 2011-10-04. Retrieved 2012-12-14.
  3. ^ "Personal Protective Equipment FAQ". Centers for Disease Control and Prevention. Archived from the original on 2013-05-16. Retrieved 2013-06-08.
  4. ^ "Glove Use Information Leaflet" (PDF). Archived (PDF) from the original on 2017-08-30. Retrieved 2022-03-28.
  5. ^ a b S. Robert Lathan (2010). "Caroline Hampton Halsted: the first to use rubber gloves in the operating room". Proc (Bayl Univ Med Cent). 23 (4): 389–92. doi:10.1080/08998280.2010.11928658. PMC 2943454. PMID 20944762.
  6. ^ "Hopkins Ceases Use Of Latex Gloves During Surgery". WJZ-TV. January 15, 2008. Archived from the original on October 11, 2008. Retrieved 2010-03-03.
  7. ^ "Rubber Gloves". Johns Hopkins Hospital. January 14, 2008. Archived from the original on 2008-12-19. Retrieved 2010-03-03.
  8. ^ Brown, Walter (December 12, 2016). "The History of Disposable Gloves". Blog.ammex.com. Archived from the original on April 26, 2021. Retrieved March 24, 2021.
  9. ^ "Ansell – Our history". Ansell.com. Archived from the original on 2021-03-19. Retrieved 2021-03-24.
  10. ^ "Surgeon's glove having improved donning properties". Patents.google.com. Archived from the original on 6 April 2022. Retrieved 25 October 2021.
  11. ^ "100 Years of Australian Innovation – latex gloves". Archived from the original on 2009-10-15. Retrieved 2010-03-07.
  12. ^ Robert Ramotowski (2012-10-18). Lee and Gaensslen's Advances in Fingerprint Technology, Third Edition. CRC Press. pp. 171–. ISBN 978-1-4200-8837-3.
  13. ^ "Watergate". Spartacus.Schoolnet.co.uk. Archived from the original on 2012-12-03. Retrieved 2012-12-14.
  14. ^ "Disposable Gloves Market Trends & Growth Report, 2020–2028". Grandviewresearch.com. Archived from the original on 2021-04-20. Retrieved 2021-04-21.
  15. ^ Linderman, Ulket; Mendoza, Martha (2020-03-24). "Malaysia makes 3 out of 4 of the world's medical gloves. The factories are operating at half capacity". Chicago Tribune. Archived from the original on 2021-04-21. Retrieved 2021-04-21.
  16. ^ a b Bhutta, Mahmood; Santhakumar, Arthy (2016). In good hands – Tackling labour rights concerns in the manufacture of medical gloves. British Medical Association.
  17. ^ "USA: Dep't of Labor adds Malaysian rubber gloves to list of forced labour-produced goods following revelations of migrant worker abuse". Business & Human Rights Resource Centre (in Spanish). Archived from the original on 2021-04-21. Retrieved 2021-04-21.
  18. ^ Swedwatch (2010). Papyrus Sweden ABs purchase of nitrile gloves from Malaysia. Stockholm.{{cite book}}: CS1 maint: location missing publisher (link)
  19. ^ Zsombor, Peter (2019-10-11). "US Ban on Malaysian Glove Maker Highlights "Systemic" Labor Abuse". VOA News. Archived from the original on 2021-04-21. Retrieved 2021-04-21.
  20. ^ "U.S. lifts ban on Malaysian medical glove maker amid shortage". Reuters. 2020-03-25. Archived from the original on 2021-04-21. Retrieved 2021-04-21.
  21. ^ "Surgical Gloves Size Chart". Surgicalglove.net. Archived from the original on 2017-05-14. Retrieved 2017-05-21.
  22. ^ "How To Choose Your Gloves Wisely?". Neobexmedical.com. 5 April 2021. Archived from the original on 2021-04-27. Retrieved 2021-04-27.
  23. ^ Berguer R, R; Hreljac, A (2004). "The relationship between hand size and difficulty using surgical instruments: a survey of 726 laparoscopic surgeons". Surgical Endoscopy. 18 (3): 508–512. doi:10.1007/s00464-003-8824-3. PMID 15100896. S2CID 24116170.
  24. ^ a b c Robert Lowes (March 21, 2016). "FDA Proposes Ban of Powdered Medical Gloves". Medscape. Archived from the original on September 23, 2017. Retrieved March 22, 2016.
  25. ^ Lambert, B. J.; Tang, F.-W.; Rogers, W. J. (2001). Polymers in Medical Applications. iSmithers Rapra Publishing. p. 77. ISBN 978-1-85957-259-7.
  26. ^ "FDA proposes ban on most powdered medical gloves". Fda.gov. March 21, 2016. Archived from the original on April 25, 2019. Retrieved December 16, 2019.
  27. ^ "FDA bans most powdered gloves". Ada.org. Archived from the original on 25 October 2021. Retrieved 25 October 2021.
  28. ^ "Federal Register :: Banned Devices; Powdered Surgeon's Gloves, Powdered Patient Examination Gloves, and Absorbable Powder for Lubricating a Surgeon's Glove". Archived from the original on 2018-01-11. Retrieved 2018-01-11.
  29. ^ Handbook on Medical and Surgical Disposable Products. Niir Project Consultancy Services. 2014. p. 43. ISBN 978-93-81039-28-1.
  30. ^ "User Labeling for Devices that Contain Natural Rubber (21 CFR 801.437); Small Entity Compliance Guide". Food and Drug Administration. Archived from the original on 2016-09-06. Retrieved 2017-11-13.
  31. ^ Medical Glove Powder Report (Report). U.S. Food and Drug Administration. September 1997. Archived from the original on May 12, 2016. Retrieved June 2, 2016.
  32. ^ Lan, Jian. "Production Process: Power Gloves VS Powder Free Gloves". YICHANG. Archived from the original on 2021-11-12. Retrieved 2021-11-12.
  33. ^ Brehler R, Kütting B (2001). "Natural Rubber Latex Allergy A Problem of Interdisciplinary Concern in Medicine". Archives of Internal Medicine. 161 (8). JAMA: 1057–1064. doi:10.1001/archinte.161.8.1057. PMID 11322839. Archived from the original on 9 February 2020. Retrieved 10 May 2020.
  34. ^ "User Labeling for Devices that Contain Natural Rubber (21 CFR 801.437); Small Entity Compliance Guide". Food and Drug Administration. Archived from the original on 2012-11-03. Retrieved 2012-12-14.
  35. ^ "Polyisoprene Surgical Gloves". SurgicalGlove.net. Archived from the original on 2008-09-18. Retrieved 2012-12-14.
  36. ^ a b "Acrobat Accessibility Report" (PDF). Nps.gov. Archived (PDF) from the original on 19 June 2015. Retrieved 25 October 2021.
  37. ^ Tanner, J; Parkinson, H (2006). "Double gloving to reduce surgical cross-infection". The Cochrane Database of Systematic Reviews. 2006 (3): CD003087. doi:10.1002/14651858.CD003087.pub2. PMC 7173754. PMID 16855997.
  38. ^ Mischke, C; Verbeek, J (2014). "Gloves, extra gloves or special types of gloves for preventing percutaneous exposure injuries in healthcare personnel". The Cochrane Database of Systematic Reviews. 2014 (3): CD009573. doi:10.1002/14651858.CD009573.pub2. PMC 10766138. PMID 24610769.
  39. ^ Kramer, Axel; Assadian, Ojan (2016-01-12). "Indications and the requirements for single-use medical gloves". GMS Hygiene and Infection Control. 11: Doc01. doi:10.3205/dgkh000261. ISSN 2196-5226. PMC 4714734. PMID 26816673.
  NODES
admin 4
Association 1
innovation 1
INTERN 1
Note 1
Project 1
USERS 1