Skip to main content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
BMC Oral Health. 2022; 22: 649.
Published online 2022 Dec 28. doi: 10.1186/s12903-022-02668-3
PMCID: PMC9798582
PMID: 36577985

Comparison of five single-file systems in the preparation of severely curved root canals: an ex vivo study

Associated Data

Supplementary Materials
Data Availability Statement

Abstract

Background

The ex vivo study is to compare the root canal preparation outcomes achieved by five nickel–titanium single-file instrumentation systems (M3-L, Reciproc Blue, V-Taper 2H, WaveOne Gold, XP-endo Shaper) in severely curved molar root canals.

Methods

A total of 60 root canals were selected from extracted human molar teeth with curvatures ranging from 25° to 50° and divided into five groups based on the instrumentation system employed (n = 12). Before and after root canal preparation, a Micro-CT scan was taken, and pre- and post-operative data were analyzed to evaluate the following parameters: volume increment of root canals (VI), untouched root canal areas (UTA), and canal transportation (CT). Apically extruded debris (AD) was collected during preparation. After that, all samples were separated into two parts and examined respectively by scanning electron microscope (SEM) to assess cleaning ability. Data were statistically analyzed with ANOVA (UTA, AD, VI) or Kruskal–Wallis test (CT, SEM-score), the level of significance was set at α = 0.05.

Results

There were no significant differences between the five systems regarding the AD, VI, and UTA parameters (P > 0.05). In terms of CT, no significant difference was noted at the straight section of canal and apical levels, while XP-endo Shaper showed less canal transportation than M3-L at the level of curved vertex (P < 0.05), and the centering ability of V-Taper 2H was significantly better than WaveOne Gold at the initial point of bending (P < 0.05). Debris and smear layers were present on the canal walls of all specimens, the apical thirds of the canal presented higher SEM scores than the coronal thirds in all groups (P < 0.05). Reciproc Blue and XP-endo Shaper showed fewer smear scores than WaveOne Gold in the apical thirds (P < 0.01 and P < 0.05, respectively), and no statistical difference was found between other groups in the middle and coronal thirds.

Conclusion

The five single-file systems evaluated performed equally in apically debris extrusion, dentin removal, and untouched root canal areas, while XP-endo Shaper and V-Taper 2H resulted in less canal transportation compared to M3-L and WaveOne Gold. Regarding cleaning ability, Reciproc Blue and XP-endo Shaper were associated with less smear layer than WaveOne Gold in the apical thirds.

Supplementary Information

The online version contains supplementary material available at 10.1186/s12903-022-02668-3.

Keywords: Canal preparation, NiTi instrumentation, Single-file system, Apically debris extrusion, Shaping ability, Cleaning ability, Micro-CT, SEM

Background

Thorough cleaning of root canals is the key step in root canal therapy and is considered critical for successful endodontic treatment because of the anatomical complexity of root canal systems [14]. In particular, the curved root canal has so far been a challenge to dentists. Studies have shown that most root canals of molars have some degree of curvature at the apical and cervical thirds, to a certain extent, irrespective of the plane of analysis [5]. Curved root canal preparation presents a greater incidence of procedural errors including root canal transportations, root perforations, and separation of instruments than straight canals [6]. Besides, it is pertinent to note that debris removal is much more difficult in the curved regions, thus leaving certain areas of root canal walls untouched, which may harbor bacteria and result in postoperative endodontic disease [7].

Compared with traditional stainless steel manual instruments, the nickel–titanium file system is superior in maintaining the original canal path to the greatest extent [8], which is eminently suitable for the preparation of curved root canals. However, the files of the original NiTi instruments are stiff and remain vulnerable to fracture due to cyclical and torsional failure [9]. Over the last decades, to circumvent such limitations, the nickel–titanium instrument has made great progress [10]. To improve flexibility and cyclic fatigue resistance, the manufacturers have sought innovation in metallurgy, instrument design, and movement strategies such as various thermo-mechanical treatments, different cross-sectional designs, and new manufacturing processes, leading to a great variety of these endodontic instruments. Among them, the single-file system has been widely used because it greatly enhanced the efficiency of clinical work, thus relieving the patient’s pain and the work intensity of dentists [11, 12]. Therefore, it is necessary to evaluate the preparation outcome of these various types of single-file systems in curved canals to provide guidance for the dentists.

WaveOne Gold (WOG, Dentsply Sirona, Switzerland), and Reciproc Blue (RB, VDW, Germany) are two popular nickel–titanium single-file systems using reciprocating motion. Their unique surface color comes from a proprietary thermal treatment process, which gave them more flexibility and resistance to cyclic bending fatigue than conventional NiTi instruments. XP-endo Shaper (XP, FKG Dentaire SA, Switzerland) is a single-file system newly introduced which is manufactured from MaxWire alloy. It’s claimed that the unique patent design of the instrument can accomplish a preparation of at least 30/04 in size from the original size while maintaining the root canal anatomy and avoiding canal transportation [13]. V-Taper 2H (VT, SSWhite, America) and M3-L (ML, Yirui, China) are CM wire-based NiTi rotary systems. This kind of wire has a controlled memory effect and is extremely flexible. The V-Taper 2H system is an updated version of the traditional NiTi instrument V-Taper 2, with the same cross-section and variable taper [14]. The M3-L system has a traditional double S-shaped cross-section with a unique longitudinal cutting plane, which can increase the space for debris removal. In terms of the mechanical property, all the five systems have good elasticity and flexibility, which are suitable for the preparation of severely curved root canals.

Up to now, a certain number of studies have been performed to assess the canal preparation outcomes of WOG and RB from different aspects. However, literature about XP, VT, and ML were scarce, and there is a lack of research that has developed a comprehensive comparison between these five single-file systems concerning both the shaping ability and cleaning efficiency in preparing severely curved root canals. Therefore, the objective of this study was to assess the apical debris extrusion, shaping, and cleaning ability of the five single-file instrumentation systems above in severely curved molar root canals, using micro-CT scan technology and scanning electron microscopy. The null hypothesis tested was no difference existed between the five systems in severely curved root canal preparation.

Materials and methods

Specimen selection and preparation

The sample size was calculated by an effect size of 0.6 determined based on a previous study [15], an alpha-type error of 0.05, and a study power of 0.95, using the F tests family and a priori power analysis (G*Power 3.1.9.3; Heinrich Heine University, Dusseldorf, Germany). The estimated sample size was 60 specimens in total.

Human permanent molar teeth extracted for reasons unrelated to this study were collected and preliminary scanned by micro-CT (SkyScan1176; Bruker, Kontich, Belgium). Finally, 60 of the 100 molars were selected for the study with the following criteria (Table 1). The molars were scanned at 80 kV and 309µA using a pixel size of 9 μm. 180° rotation around the vertical axis and a 0.1-mm-thick copper plus aluminum filter were selected. After scanning, the data were reconstructed using NRecon v.1.18.8.0 software (Bruker, Kontich, Belgium), with smoothing of 5, ring artifacts reduction of 12, beam hardening correction of 30% to distinguish the density of dentin, and presenting the true internal structure of root canal. Region of interest (ROI) was established from the furcation level to the apex of the root, resulting in 600–700 cross-sections per specimen. For each tooth, only one qualified root canal was selected, and the maximum curvature of each root canal was recorded. All the molars were cleaned using an ultrasonic cleaner to remove the periodontal membrane and calculus and stored in 1% chloramine-T (Sinopharm Chemical ReagentCo., Ltd, China) solution at 4 ℃ for the next procedure [16].

Table 1

The exclusion and inclusion criteria of specimen

Inclusion criteriaExclusion criteria
a. Fully formed apex without fracture.a. Long oval-shaped canals ( the ratio of the long to short canal diameter was > 2).
b. One independent severely curved root canal with a curvature of 25° to 50° according to the Schneider method [17].b. Root resorption (internal, external, or apical) or calcifications.
c. Previous endodontic treatment.

Crown access was obtained using diamond burs according to the morphology of the pulp chamber, the canal orifices were located and confirmed with a #10 K-file (VDW, Germany), and the model number of the initial apical file (the K-file whose tip diameter is the same as the apical foramen diameter) was determined and registered as the size of the apical foramen. 60 specimens were matched to create 12 groups of 5 teeth based on their angle of curvature and the size of the apical foramen to enable homogeneous specimen distribution in each experimental group. Then, the 5 teeth from each group were randomly allocated to 5 experimental groups (n = 12) according to the different systems they used: ML, RB, VT, WOG, and XP group. The degree of homogeneity (baseline) between groups was statistically confirmed at a significance level of 5% (P > 0.05, 1-way analysis of variance test) (Table 2).

Table 2

Characteristics of curved root canal teeth per group (n = 12)

SystemCurvature (°)Size of initial apical file
Mean ± SDMinMaxMean ± SDMinMax
M3-L35.58 ± 8.5725509.50 ± 0.90810
Reciproc Blue35.33 ± 7.6625509.50 ± 0.90810
V-Taper 2H34.92 ± 7.8825499.67 ± 0.78810
WaveOne Gold35.42 ± 8.0725489.33 ± 0.98810
XP-endo Shaper37.75 ± 8.2727509.33 ± 0.98810
P value (ANOVA)0.920.89

Root canal preparation

To avoid apical transportation before preparation, the working length (WL) was determined by introducing a pre-curved #06 K-file into the canal until it was visible at the main apical foramen and then withdrawing it 0.5 mm. A glide path was established after manual preparation up to ISO 15/0.02 using stainless K-files, and no coronal expansion was conducted to prevent interfering with coronal transportation. Then, root canal preparations were performed using the different nickel–titanium systems in each system according to the manufacturer’s instructions. In the ML group, the L2 file (25/06.5) was used in rotary motion at a speed of 350 rpm and torque of 2.5 Ncm; in RB group, the R25 file having a tip size of 25 and a 0.08 taper over the first 3 mm was utilized in a reciprocating mode; in VT group, the V25/06 file was used at 350 rpm and 2 Ncm in rotary motion; in WOG group, the primary file (25/07 red) was employed with a reciprocating mode; in XP group, the file was operated at 800 rpm and 1 Ncm in rotary motion.

All of the files were gently inserted into the root canals and applied with light up-and-down movements with light apical pressure at a distance of 1 mm (3 to 5 up-and-down strokes every time). It was necessary that the canals remain moist during preparation. After every 3 to 5 up-and-down strokes, if the WL was not achieved, the file should be withdrawn from the root canal while rotating, followed by irrigation of the canal with 2 mL 2.5% NaOCl (Longly, Wuhan, China) for 30 s. Then the patency was rechecked with a #6 K-file, and after that, the preparation was restarted again. The operations above were repeated until the WL was reached. In the XP group, the file was moved up and down over the entire length five times after it reached the WL to achieve the final size of approximately 30/04. Final irrigation was performed by rinsing 5 mL of 2.5% NaOCl solution for 1 min at a distance of 1 mm from the WL. A total of 15 mL of flushing fluid was used for each root canal using a syringe with a 30-guide-vented NaviTip irrigation needle (Ultradent, South Jordan, America). To eliminate bias owing to instrument fatigue, each fresh file was used to prepare only one canal. All instrumentation operations were conducted by a single endodontist with 10 years of clinical experience in a 37 ℃ incubator (TAISITE, Tianjin, China), and no accidents or errors like instrument fractures occurred during root canal preparation in the 5 groups.

Debris assessment

The whole preparation process described above was performed in an apically extruded debris collection device adapted from a past report [18] (Fig. 1). The tooth was fixed with wax at the level of cementoenamel junction (CEJ) in a circular opening made in the separated cap of a 10 mL Eppendorf tube large enough to hold it. Then a 50 mL glass bottle with a rubber stopper was prepared, digging a round hole in the rubber stopper with the same diameter as the Eppendorf tube, and inserting the tube into the glass bottle to avoid fouling during preparation and interference with the weighing result. Afterward, a 5 mL disposable syringe needle was inserted into the tube cap to balance the internal and external pressures. Finally, the glass bottle is wrapped in tinfoil to prevent the operator from seeing the debris extrusion.

An external file that holds a picture, illustration, etc.
Object name is 12903_2022_2668_Fig1_HTML.jpg

Apically extruded debris collection device

Before preparation, the Eppendorf tube was weighed by cap removal (average weight three times, precision 0.0001 g) using the precision balance (CP214C, OHAUS, America) (Additional file 1). After preparation, the debris adhering to the root surface was collected by washing the root with 1ml distilled water while in the tube. Being dried in an oven at 110 °C for 5 h, the Eppendorf tube containing dentin debris was weighed by cap removal again (average weight three times, precision 0.0001 mg). The difference in weighing results was calculated, which was the amount of apically extruded debris (AD).

Evaluation of shaping ability

The specimens were rescanned and reconstructed after canal preparation, with the same parameters as the initial scan. The pre- and post-preparation data were imported into Mimics Research v.20.0 software (Materialise, Leuven, Belgium) for 3D reconstruction and analysis. The pre- and post-preparation root canals were visualized and colored green and red, respectively, and the volumes of the pre- and post-preparation canals were measured, allowing the percentage of increment in root canal volume (%VI) to be calculated. The Mimics “Align” function was employed to calibrate and superimpose the root canal 3D models before and after preparation (Fig. 2). The untouched root canal areas (UTA) could be displayed (the green areas) and the percentage of UTA could be estimated using the formula: The number of static voxels × 100/total number of surface voxels. For analysis of root canal transportation, the “Fit Centerline” function of Mimics was used to fit the axial centerlines of root canals before and after instrumentation, canal transportation (CT) could be obtained by measuring the distance between the two central points of the cross-section images at seven levels (P1-P7) selected in advance: 1-, 2-, 3-mm distance from the apical foramen, the curved vertex, the initial point of bending, root canal orifice and the midpoint between the canal orifice to the initial point of bending (Fig. 3).

An external file that holds a picture, illustration, etc.
Object name is 12903_2022_2668_Fig2_HTML.jpg

Three-dimensional reconstruction of the root canal. a Preoperative root canal (in green). b Postoperative root canal (in red). c The superimposition of root canals before and after preparation, the green regions on the surface presented the untouched areas

An external file that holds a picture, illustration, etc.
Object name is 12903_2022_2668_Fig3_HTML.jpg

Three-dimensional reconstruction of the root canal. a The centerlines of the root canal before (in green) and after preparation (in red). b P1-P7 were selected in advance. c, d The representative photo of measurement of canal transportation in P1

Evaluation of cleaning ability by scanning electron microscopy (SEM)

After micro-CT scanning, two shallow grooves were created longitudinally on the buccal and lingual sides of the root. The grooves should run parallel to the curve of the root canal and not puncture it. Then the root was split in half using a hammer and chisel. The root canal orifices were blocked by sterile small cotton balls to prevent the contamination of canals throughout the process. Freeze-drying at − 80 ℃ for 24 h (Lyo Quest, Telstar, Spain), the split roots were sprayed with gold for the following SEM examination.

Both the two parts of all canals were assessed, and two fields of the canal walls were randomly selected, respectively, in the coronal, middle, and apical thirds to be photomicrographed under × 100 and × 5000 magnification. The debris and smear layer in each region were scored using the scoring system proposed by Gutmann [19]. The debris was given a score of 1–4 according to the proportion of the surface covered by debris. The smear layer was scored based on the area covered by the smear layer and whether the dentinal tubules were visible and patent. The measurements were carried out independently by two researchers blinded to group allocation, one of whom had not participated in the study design or operation. Training and agreement on criteria has been achieved prior to scoring, and once the researchers have different opinions, an accordant score will be reached after discussion. The scoring example photos were shown in Fig. 4.

An external file that holds a picture, illustration, etc.
Object name is 12903_2022_2668_Fig4_HTML.jpg

Representative SEM photos of debris (× 100) and smear layer (× 5000). a debris score 1; b debris score 2; c debris score 3; d debris score 4; e smear layer score 1; f smear layer score 2; g smear layer score 3; h smear layer score 4

Statistical analysis

The normalcy and homogeneity of variance of the data were checked by the Shapiro-Wilk test and Levene test. One-way analysis of variance (ANOVA) and the Tukey test were used to compare the 5 groups for variables that presented normal distribution (the angle of curvature, apical size, %UTA, %VI, AD). When the variables did not have a normal distribution (CT and SEM scores), the Kruskal–Wallis test was used to analyze the data, and the Mann–Whitney U test was used for multiple comparisons. The level of significance was set at 5%. Statistical Package for the Social Sciences v.21.0 (SPSS, IBM Brasil, SP, Brazil) and GraphPad Prism v.7.04 (GraphPad Software, America) was used for all analysis.

Results

Apically extruded debris, volume increment of canals, and untouched surface areas

No statistical differences were observed among the five groups regarding the apically extruded debris, the percentage of increment in root canal volume, and the percentage of untouched surface areas (P > 0.05). The details of the data were presented in Table 3.

Table 3

The details of % volume increment, % untouched surface area, and apically extruded debris (n = 12)

SystemUTA (%)AD (mg)Volume (mm3)
BeforeAfterΔV (%)
M3-L3.66 ± 3.6357.87 ± 22.368.54 ± 5.6511.26 ± 4.3782.40 ± 33.43
Reciproc Blue4.90 ± 4.9442.38 ± 21.589.51 ± 4.8112.33 ± 4.8536.96 ± 9.20
 V-Taper 2H5.65 ± 2.7058.28 ± 21.788.71 ± 4.2110.57 ± 3.9628.72 ± 7.60
WaveOne Gold3.64 ± 2.3324.95 ± 7.28.09 ± 3.0411.92 ± 2.0860.22 ± 16.11
XP-endo Shaper4.50 ± 2.9130.78 ± 9.158.26 ± 5.7211.49 ± 3.1236.83 ± 9.23
P value (ANOVA)0.560.570.970.970.21

Parameters normally distributed are presented with Mean ± SD.

Canal transportation

Table 4 displayed the results of canal transportation. The differences in the amount of canal transportation were not significant between the five groups at the straight section (P6–P7) of canals and 1, 2, 3-mm levels from the apex (P1–P3), whereas XP showed less canal transportation than ML (P < 0.05) at the level of the curve vertex (P4), and at the level of the initial point of bending (P5), the centering ability of VT was better in comparison to WOG (P < 0.05).

Table 4

The deviation of root canal transportation (mm) (n = 12)

Measuring levelsM3-LReciproc BlueV-Taper 2HWaveOne goldXP-endo shaperP value
P1

0.10 ± 0.02

(0.08, 0.05–0.14)

0.08 ± 0.02

(0.06, 0.03–0.12)

0.11 ± 0.02

(0.09, 0.04–0.18)

0.12 ± 0.02

(0.11, 0.05–0.19)

0.08 ± 0.02

(0.05, 0.02–0.11)

0.77
P2

0.12 ± 0.02

(0.12, 0.07–0.16)

0.16 ± 0.04

(0.10, 0.04–0.12)

0.16 ± 0.04

(0.06, 0.02–0.15)

0.010 ± 0.04

(0.08, 0.06–0.14)

0.08 ± 0.02

(0.07, 0.04–0.14)

0.48
P3

0.11 ± 0.02

(0.07, 0.04–0.18)

0.07 ± 0.02

(0.04, 0.02–0.12)

0.07 ± 0.02

(0.05, 0.02–0.13)

0.11 ± 0.02

(0.08, 0.06–0.17)

0.07 ± 0.02

(0.04, 0.03–0.12)

0.56
P4

0.19 ± 0.05a

(0.10, 0.08–0.30)

0.08 ± 0.03

(0.07, 0.02–0.14)

0.10 ± 0.04

(0.05, 0.04–0.15)

0.09 ± 0.02

(0.08, 0.06–0.14)

0.07 ± 0.02b

(0.05, 0.03–0.10)

0.03
P5

0.16 ± 0.05

(0.06, 0.05–0.28)

0.12 ± 0.02

(0.07, 0.06–0.16)

0.08 ± 0.03a

(0.05, 0.02–0.13)

0.20 ± 0.04b

(0.22, 0.11–0.29)

0.10 ± 0.02

(0.08, 0.05–0.17)

0.04
P6

0.16 ± 0.05

(0.11, 0.06–0.26)

0.10 ± 0.02

(0.08, 0.05–0.15)

0.10 ± 0.01

(0.11, 0.07–0.12)

0.16 ± 0.03

(0.14, 0.09–0.23)

0.09 ± 0.03

(0.07, 0.03–0.15)

0.33
P7

0.18 ± 0.05

(0.13, 0.07–0.29)

0.15 ± 0.03

(0.13, 0.08–0.22)

0.14 ± 0.05

(0.08, 0.02–0.26)

0.20 ± 0.05

(0.18, 0.11–0.31)

0.13 ± 0.05

(0.05, 0.02–0.24)

0.17
P value0.700.130.690.280.96

P1–P3: 1-, 2-, 3-mm from apical foramen; P4: curved vertex; P5: initial point of bending; P6: The midpoint of P5 and P7; P7: root canal orifice.

Parameters non-normally distributed are presented with Mean ± SE (median, range)

No statistically significant difference was found within groups (Kruskal–Wallis test and Mann–Whitney test, P > 0.05 )

“a”and “b”: different letters in the same row indicated a statistically significant difference between groups (Kruskal–Wallis test and Mann–Whitney U test, P < 0.05 )

SEM scores of debris and smear layers

The kappa values for the inter-researcher agreement were 0.87. The SEM scores of the debris and smear layer were shown in Figs. 5 and and6,6, respectively. All specimens had debris and smear layer on canal walls, and the apical thirds of the canals in all groups exhibited higher SEM scores than the coronal thirds (P < 0.05). In all three thirds, there were no significant differences in debris scores between groups, but in the apical thirds, RB and XP showed fewer smear layer scores than WOG (P < 0.01 and P < 0.05, respectively), and no statistical difference was found between the other groups in the middle and coronal thirds.

An external file that holds a picture, illustration, etc.
Object name is 12903_2022_2668_Fig5_HTML.jpg

The proportion of specimens registered for each score in the evaluation of debris

An external file that holds a picture, illustration, etc.
Object name is 12903_2022_2668_Fig6_HTML.jpg

The proportion of specimens registered for each score in the evaluation of smear layers

Discussion

The shaping ability and cleaning effectiveness of single-file instruments have been demonstrated in previous studies [20], where the single-file systems performed similarly to rotary full-sequence NiTi systems using one instrument. The present study compared the apical debris extrusion, shaping, and cleaning ability of five advanced single-file systems with different metallurgy, instrument design, as well as kinematic strategy during severely curved canals preparation.

The extrusion of apical debris was associated with post-operative pain or discomfort, so the reduction in debris extrusion is one of the important factors to evaluate the outcomes of root canal preparation. NaOCl was used as the flushing fluid in this study despite researchers suggesting that NaOCl solution leaking from the apical foramen will interfere with the measurement of apically extruded debris [21]. This is because the substance extruded from the root apex contained intracanal irrigants in addition to necrotic tissue and dental debris during in vivo endodontic operations [22]. Furthermore, a 2% NaOCl solution can better simulate the procedure in the clinic when investigating the cleaning ability of the files. It is worth noting that ethylene diamine tetracetic acid (EDTA) was not employed in this study since it can chemically react with NaOCl to generate precipitates [23], which will compromise the accuracy of the measurement of AD.

All instruments generated debris extrusion more or less through the apical foramen with no discernible difference between the five systems. This was consistent with a previous study in which XP and RB extruded similar hard tissue debris in extracted maxillary molars [24]. However, De Deus et al. found that reciprocating files caused greater debris extrusion apically in comparison to rotary instruments [25]. It has been speculated that the instruments with reciprocating motion are better at squeezing debris into the spiral flutes and carrying the debris out of the root canal orifice, thereby reducing apical extrusion of debris. Rotary instruments, on the other hand, are more likely to produce a spiral effect which may force the debris out of the apical foramen. This tendency was not observed in the present study, which may be attributed to other characteristics of the instruments such as the cross-section and taper design. The unique S-shaped design of XP makes it act like a spoon during movement, providing unparalleled debris removal; The ML instrument has a unique longitudinal cutting plane on the traditional cross-section, which increases the debris discharge space by 20%; and the VT instrument has the smallest taper design and produces less dentin debris, potentially resulting in less apical extrusion. As a result of the combined influence of multiple aspects, there were no significant differences in AD among the five systems.

The micro-CT has been used in the evaluation of the shaping ability of endodontic instruments in recent years due to its precision and nondestructive ability, and the smaller the pixel size, the greater the accuracy of the evaluation [26]. Hence, the present study chose a 9 μm pixel size at which the anatomical details of the root canal could be observed. For three-dimensional volumetric assesment of the pulp space, several 3D analysis softwares have been developed to reconstruct two-dimensional data into three dimensions and analyze it qualitatively and quantitatively, such as OsiriX MD, 3D Slicer, and Mimics. The accuracy of them has been verified in many papers compared with real measurements [2729], and the Mimics software was used in the present study. According to the findings, the volumes of canals in the five systems were similar at baseline, with no significant difference among groups. This was crucial for ensuring the validity of the results and reducing bias by confirming the work of the five systems under identical conditions. The percentage of volume increment was shown to be equal among the five systems, which was different from the study of Caviedes et al., who found significant differences of canal volume increment: RB > WOG > XP [30]. This may be related to the fact that the specimens they chose were lower premolars with a straight canal, indicating that the performance of instruments in volume increment may be affected by the curvature of the canals.

On average, the percentages of untouched root canal areas of the five systems (ML, RB, VT, WOG, and XP group) were 3.66%, 4.90%, 5.65%, 3.64%, and 4.50%, respectively, without any statistical difference among groups. These values were less than those reported in other studies, which showed that the untouched canal areas varied from 9.6 to 47.6% [3133]. The difference might be attributed to the fact that the root canal samples in this study were nearly round-shaped, with an average initial file size of 9–10. A large number of untouched areas is more likely to be observed in the root canal walls of oval or broad canals. Therefore, more studies should be conducted to evaluate these parameters in diverse canal morphologies. Despite the advances in instruments and the regular shape of canals, none of the systems could prepare all the canal walls in severely curved canals, underlining the essential role of chemomechanical preparation via irrigation strategies.

The measurement method of canal transportation was modified according to previous studies [3437]. Since the uncertainty of the direction in canal transportation, the direct measurement of central points is considered more telling. With this measuring method, it was found that the centering ability of five instruments were similar at the 1-, 2-, and 3-mm levels from the apical foramen and the straight section of canal. The canal transportation occured mainly at the level of the curved vertex and the initial point of bending with significant differences: XP showed less canal transportation than ML at the level of the curved vertex (P < 0.05), and VT resulted in better centering than WOG at the initial point of bending (P < 0.05). This agreed with another study that reported XP generated less canal transportation than WOG at the 7-mm level using the micro-CT method [38]. Moreover, Shenoi et al. also demonstrated the superior centering ability of VT compared to ProTaper Next, and HyFlex CM in curved canals [39]. Gundappa et al. found that the taper was one of the main factors related to the occurrence of canal transportation in a meta-analysis of the centering ability of NiTi instruments [40]. Instruments with small taper had good flexibility, which could better maintain the original axial direction of the root canal, reducing canal transportation but resulting in less dentin removal. The XP instrument is manufactured from Max-wire with a fixed small taper of 0.01, which endows it with super-elasticity and extreme flexibility. It has a “Booster tip” design, and this non-cutting tip with six cutting edges can provide optimal guidance for the instrument and maintain the original curvature when passing through root canals. The VT instrument is a CM wire-based NiTi instrument with superior flexibility and resistance to cyclic fatigue. It has a variable taper design like WG, RB, and ML, but its apical taper is smaller than the other three systems. It’s possible that the larger apical taper and more stiff tips of WG and ML contribute to their increased canal transportation. Nevertheless, according to Wu et al., apical canal transportation of less than 0.3 mm would have the least impact on the prognosis of root canal therapy [41]. Under this criterion, the canal transportation of the instruments assessed in this study was acceptable and the differences between systems were negligible.

The smear layer is a kind of “muddy” material that clings to the canal walls as a result of the rasping and trowelling actions of instruments in root canal preparation, including fragments of dentin, microorganisms, and necrotic tissue. It has been reported that the residual debris and smear layer on the canal walls can affect the success rate of root canal therapy. The possible mechanism is to obstruct the penetration of disinfectants and the contact between root canal walls and filling paste [4244]. In the present study, all specimens had debris and smear layer on canal walls in different groups, and the results agreed with previous findings that the apical thirds of the canal presented more amount of debris and smear layer than the coronal thirds in all systems [45, 46]. Overall, the root canal walls were fairly clean, particularly in terms of debris, which might be attributed to the physical irrigation. The smear scores were generally higher, which may be connected to the lack of chemical irrigation in our study, because the smear layer is adhered to the canal wall, it’s hard to be washed off by simple physical irrigation without the supplementary use of chemical irrigation. In practical situations, a combination of EDTA and NaOCl could achieve a better chemical preparation effect. Nonetheless, the outcomes of the present study were comparable since this experiment was a contrast experiment of the five instruments and the irrigation strategies were the same.

There were no significant differences in debris scores across groups on the entire surface of canals. As for the smear scores, no significant differences were found in the middle and coronal thirds, but in the apical thirds, RB and XP were shown to have fewer smear scores than WOG (P < 0.01 and P < 0.05, respectively). It has been concluded that the cutting efficiency [47] and cross-sectional area [48] of the files play significant roles in the production of debris and smear layer. This may explain the difference between RB and WOG, which are both subjected to special heat treatment with different cross-section designs. The WOG file has an offset parallelogram geometry leaving one cutting edge in contact with the canal wall, which reduces the risk of taper lock but may lead to less scraping of canal walls. The cross-section of RB is S-shaped with two cutting edges, which is highly efficient in cutting and has a smaller cross-section area than WOG. Therefore, sharp cutting edges and a larger chip space may aid in the elimination of the smear layer. The superior cleaning ability of XP may be related to its unique design. Because of the peculiarity of Max-wire, XP can change its morphology into a semi-circular spoon shape when rotating. Then it can protrude to the canal wall and expand or contract according to the shape of the root canal to obtain an appropriate cleaning of the canal walls. Besides, the ML file has a double S-shaped cross-section, and the VT file has a modified convex triangle cross-section with three cutting edges, both are smaller than that of WOG, therefore their SEM scores were lower on average than WOG, but the difference was not significant. To our knowledge, there have been no SEM analyses of the cleaning efficiency of ML and VT until now, so no comparison could be made.

Conclusion

Within the limitations of this ex vivo study, it can be concluded that the newly introduced NiTi instruments XP-endo Shaper, V-Taper 2H, and M3-L performed equally to WaveOne Gold and Reciproc Blue in apically debris extrusion, dentin removal, and untouched root canal areas during the preparation of severely curved canals. None of the instruments were able to implement perfect centering and cleaning of root canals, however, XP-endo Shaper and V-Taper 2H resulted in less canal transportation than M3-L and WaveOne Gold at the curved section. Reciproc Blue and XP-endo Shaper were associated with less smear layer compared to WaveOne Gold in the apical thirds. Further research will be required to verifiy these results in the future.

Acknowledgements

We thank the Medical Subcenter of HUST Analytical & Testing Center in data acquisition.

Abbreviations

VIVolume increment of root canals
UTAUntouched root canal areas
CTCanal transportation
ADApically extruded debris
SEMScanning electron microscope
WOGWaveOne Gold
RBReciproc Blue
XPXP-endo Shaper
VTV-Taper 2H
MLM3-L
WLWorking length
CEJCementoenamel junction
EDTAEthylene diamine tetracetic acid.

Authors’ contributions

Guided the study: MQD. Designed the experiment: YNL, CL. Performed the experiment: YNL, MZC, CL. Collected and analyzed the data: YNL, MZC, TWL. Wrote the manuscript: YNL. Review & Editing the manuscript: YNL, MQD, CL. All authors have read and approved the final manuscript.

Funding

The study is supported by independent & interdisciplinary research projects of Wuhan University [grant numbers 2042018kf0237].

Availability and data materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Declarations

Ethics approval and consent to participate

All methods in the current study were performed in accordance with the Declaration of Helsinki. The study protocol was approved by the Ethics Committee of the School and Hospital of Stomatology, Wuhan University, China (approval number No.2020/B12).

The human molar teeth used in the present study were all isolated teeth extracted at the Stomatological Hospital of Wuhan University for reasons unrelated to the study. Because it is impracticable to associate each tooth with the patient and contact them to gain informed consent, the need of informed consent requirement was waived with the approval of the Ethics Committee of the School and Hospital of Stomatology, Wuhan University, China.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Chang Liu, nc.ude.uhw@8270cuil.

Minquan Du, nc.ude.uhw@nauqnimud.

References

1. Stringheta CP, Bueno CES, Kato AS, Freire LG, Iglecias EF, Santos M, et al. Micro-computed tomographic evaluation of the shaping ability of four instrumentation systems in curved root canals. Int Endod J. 2019;52(6):908–16. doi: 10.1111/iej.13084. [PubMed] [CrossRef] [Google Scholar]
2. Mirza MB, Gufran K, Alhabib O, Alafraa O, Alzahrani F, Abuelqomsan MS, et al. CBCT based study to analyze and classify root canal morphology of maxillary molars - a retrospective study. Eur Rev Med Pharmacol Sci. 2022;26(18):6550–60. [PubMed] [Google Scholar]
3. Yang L, Han J, Wang Q, Wang Z, Yu X, Du Y. Variations of root and canal morphology of mandibular second molars in chinese individuals: a cone-beam computed tomography study. BMC Oral Health. 2022;22(1):274. doi: 10.1186/s12903-022-02299-8. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
4. Xu LJ, Zhang JY, Huang ZH, Wang XZ. Successful individualized endodontic treatment of severely curved root canals in a mandibular second molar: a case report. World J Clin Cases. 2022;10(14):4632–9. doi: 10.12998/wjcc.v10.i14.4632. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
5. Estrela C, Bueno MR, Barletta FB, Guedes OA, Porto OC, Estrela CR, et al. Identification of apical and cervical curvature Radius of Human Molars. Braz Dent J. 2015;26(4):351–6. doi: 10.1590/0103-64402013x0252. [PubMed] [CrossRef] [Google Scholar]
6. Estrela C, Pecora JD, Estrela CRA, Guedes OA, Silva BSF, Soares CJ, et al. Common operative procedural errors and clinical factors Associated with Root Canal Treatment. Braz Dent J. 2017;28(2):179–90. doi: 10.1590/0103-6440201702451. [PubMed] [CrossRef] [Google Scholar]
7. da Silva Limoeiro AG, Dos Santos AH, De Martin AS, Kato AS, Fontana CE, Gavini G, et al. Micro-computed tomographic evaluation of 2 nickel–titanium instrument systems in shaping root canals. J Endod. 2016;42(3):496–9. doi: 10.1016/j.joen.2015.12.007. [PubMed] [CrossRef] [Google Scholar]
8. Del Fabbro M, Afrashtehfar KI, Corbella S, El-Kabbaney A, Perondi I, Taschieri S. In vivo and in vitro effectiveness of rotary nickel–titanium vs manual stainless steel instruments for root canal therapy: systematic review and meta-analysis. J Evid Based Dent Pract. 2018;18(1):59–69. doi: 10.1016/j.jebdp.2017.08.001. [PubMed] [CrossRef] [Google Scholar]
9. Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel–titanium files after clinical use. J Endod. 2000;26(3):161–5. doi: 10.1097/00004770-200003000-00008. [PubMed] [CrossRef] [Google Scholar]
10. Gavini G, Santos MD, Caldeira CL, Machado MEL, Freire LG, Iglecias EF, et al. Nickel–titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res. 2018;32(suppl 1):e67. doi: 10.1590/1807-3107bor-2018.vol32.0067. [PubMed] [CrossRef] [Google Scholar]
11. Liang YH, Yue L. Root canal treatment: key steps in root canal instrumentation and improvement of nickel–titanium endodontic instruments. Zhonghua Kou Qiang Yi Xue Za Zhi. 2019;54(10):717–20. [PubMed] [Google Scholar]
12. Campbell F, Cunliffe J, Darcey J. Current technology in endodontic instrumentation: advances in metallurgy and manufacture. Br Dent J. 2021;231(1):49–57. doi: 10.1038/s41415-021-3170-1. [PubMed] [CrossRef] [Google Scholar]
13. Azim AA, Piasecki L, da Silva Neto UX, Cruz ATG, Azim KA. XP shaper, a Novel Adaptive Core Rotary Instrument: micro-computed tomographic analysis of its shaping Abilities. J Endod. 2017;43(9):1532–8. doi: 10.1016/j.joen.2017.04.022. [PubMed] [CrossRef] [Google Scholar]
14. Chang SW, Shim KS, Kim YC, Jee KK, Zhu Q, Perinpanayagam H, et al. Cyclic fatigue resistance, torsional resistance, and metallurgical characteristics of V taper 2 and V taper 2H rotary NiTi files. Scanning. 2016;38(6):564–70. doi: 10.1002/sca.21301. [PubMed] [CrossRef] [Google Scholar]
15. Kabil E, Katić M, Anić I, Bago IJJoe. Micro-computed evaluation of Canal Transportation and Centering ability of 5 rotary and Reciprocating Systems with different Metallurgical Properties and Surface Treatments in Curved Root Canals. 2021;47(3):477–84. [PubMed]
16. Zheng TL, Huang C, Zhang ZX, Wang S, Zhang G. Influence of storage methods on microtensile bond strength of dentin adhesive system. Shanghai Kou Qiang Yi Xue. 2005;14(2):147–50. [PubMed] [Google Scholar]
17. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32(2):271–5. doi: 10.1016/0030-4220(71)90230-1. [PubMed] [CrossRef] [Google Scholar]
18. Myers GL, Montgomery S. A comparison of weights of debris extruded apically by conventional filing and Canal Master techniques. J Endod. 1991;17(6):275–9. doi: 10.1016/S0099-2399(06)81866-2. [PubMed] [CrossRef] [Google Scholar]
19. Gutmann JL, Saunders WP, Nguyen L, Guo IY, Saunders EM. Ultrasonic root-end preparation. Part 1. SEM analysis. Int Endod J. 1994;27(6):318–24. doi: 10.1111/j.1365-2591.1994.tb00276.x. [PubMed] [CrossRef] [Google Scholar]
20. Burklein S, Hinschitza K, Dammaschke T, Schafer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J. 2012;45(5):449–61. doi: 10.1111/j.1365-2591.2011.01996.x. [PubMed] [CrossRef] [Google Scholar]
21. Elmsallati EA, Wadachi R, Suda H. Extrusion of debris after use of rotary nickel–titanium files with different pitch: a pilot study. Aust Endod J. 2009;35(2):65–9. doi: 10.1111/j.1747-4477.2008.00128.x. [PubMed] [CrossRef] [Google Scholar]
22. Lambrianidis T, Tosounidou E, Tzoanopoulou M. The effect of maintaining apical patency on periapical extrusion. J Endod. 2001;27(11):696–8. doi: 10.1097/00004770-200111000-00011. [PubMed] [CrossRef] [Google Scholar]
23. Rossi-Fedele G, Doğramaci E, Guastalli A, Steier L, de Figueiredo J. Antagonistic interactions between sodium hypochlorite, chlorhexidine, EDTA, and citric acid. J Endod. 2012;38(4):426–31. doi: 10.1016/j.joen.2012.01.006. [PubMed] [CrossRef] [Google Scholar]
24. Alves FRF, Paiva PL, Marceliano-Alves MF, Cabreira LJ, Lima KC, Siqueira JF, Jr, et al. Bacteria and hard tissue debris extrusion and intracanal bacterial reduction promoted by XP-endo shaper and reciproc instruments. J Endod. 2018;44(7):1173–8. doi: 10.1016/j.joen.2018.04.007. [PubMed] [CrossRef] [Google Scholar]
25. De-Deus G, Belladonna FG, Silva EJ, Marins JR, Souza EM, Perez R, et al. Micro-CT evaluation of non-instrumented canal areas with different enlargements performed by NiTi Systems. Braz Dent J. 2015;26(6):624–9. doi: 10.1590/0103-6440201300116. [PubMed] [CrossRef] [Google Scholar]
26. Peters OA, Laib A, Ruegsegger P, Barbakow F. Three-dimensional analysis of root canal geometry by high-resolution computed tomography. J Dent Res. 2000;79(6):1405–9. doi: 10.1177/00220345000790060901. [PubMed] [CrossRef] [Google Scholar]
27. Shetty H, Shetty S, Kakade A, Shetty A, Karobari M, Pawar A, et al. Three-dimensional semi-automated volumetric assessment of the pulp space of teeth following regenerative dental procedures. Sci Rep. 2021;11(1):21914. doi: 10.1038/s41598-021-01489-8. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
28. Phienwej K, Chaiworawitkul M, Jotikasthira D, Khwanngern K, Sriwilas P, et al. Comparison of preoperative measurement methods of alveolar cleft volume using cone beam computed tomography between computer simulation and water displacement methods. Cleft Palate Craniofac. 2021 doi: 10.1177/105566562110556. [PubMed] [CrossRef] [Google Scholar]
29. Wang D, Jiang H, Pan B, Yang Q, He L, Sun H, et al. Standardized measurement of auricle: a method of high-precision and reliability based on 3D scanning and mimics software. Exp Ther Med. 2019;18(6):4575–82. [PMC free article] [PubMed] [Google Scholar]
30. Caviedes-Bucheli J, Rios-Osorio N, Usme D, Jimenez C, Pinzon A, Rincon J, et al. Three-dimensional analysis of the root canal preparation with Reciproc Blue(R), WaveOne Gold(R) and XP EndoShaper(R): a new method in vivo. BMC Oral Health. 2021;21(1):88. doi: 10.1186/s12903-021-01450-1. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
31. Siqueira JF, Jr, Alves FR, Versiani MA, Rocas IN, Almeida BM, Neves MA, et al. Correlative bacteriologic and micro-computed tomographic analysis of mandibular molar mesial canals prepared by self-adjusting file, reciproc, and twisted file systems. J Endod. 2013;39(8):1044–50. doi: 10.1016/j.joen.2013.04.034. [PubMed] [CrossRef] [Google Scholar]
32. Zhao D, Shen Y, Peng B, Haapasalo M. Root canal preparation of mandibular molars with 3 nickel–titanium rotary instruments: a micro-computed tomographic study. J Endod. 2014;40(11):1860–4. doi: 10.1016/j.joen.2014.06.023. [PubMed] [CrossRef] [Google Scholar]
33. Drukteinis S, Peciuliene V, Dummer PMH, Hupp J. Shaping ability of BioRace, ProTaper NEXT and genius nickel–titanium instruments in curved canals of mandibular molars: a MicroCT study. Int Endod J. 2019;52(1):86–93. doi: 10.1111/iej.12961. [PubMed] [CrossRef] [Google Scholar]
34. de Carvalho GM, Sponchiado Junior EC, Garrido AD, Lia RC, Garcia Lda F, Marques AA. Apical transportation, centering ability, and cleaning effectiveness of reciprocating single-file System Associated with different glide path techniques. J Endod. 2015;41(12):2045–9. doi: 10.1016/j.joen.2015.09.005. [PubMed] [CrossRef] [Google Scholar]
35. Belladonna FG, Carvalho MS, Cavalcante DM, Fernandes JT, de Carvalho Maciel AC, Oliveira HE, et al. Micro-computed tomography shaping ability assessment of the new blue thermal treated reciproc instrument. J Endod. 2018;44(7):1146–50. doi: 10.1016/j.joen.2018.03.008. [PubMed] [CrossRef] [Google Scholar]
36. Elashiry MM, Saber SE, Elashry SH. Comparison of shaping ability of different single-file systems using microcomputed tomography. Eur J Dent. 2020;14(1):70–6. doi: 10.1055/s-0040-1701393. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
37. Xu F, Zhang Y, Gu Y, Ping Y, Zhou R, Wang J. Shaping ability of four single-file systems in the instrumentation of second mesiobuccal canals of three-dimensional printed maxillary first molars. Ann Transl Med. 2021;9(18):1425. doi: 10.21037/atm-21-3855. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
38. Poly A, AlMalki F, Marques F, Karabucak B. Canal transportation and centering ratio after preparation in severely curved canals: analysis by micro-computed tomography and double-digital radiography. Clin Oral Investig. 2019;23(12):4255–62. doi: 10.1007/s00784-019-02870-8. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
39. Shenoi PR, Luniya DA, Badole GP, Makade CS, Kubde R, Khode RT. Comparative evaluation of shaping ability of V-Taper 2H, ProTaper Next, and HyFlex CM in curved canals using cone-beam computed tomography: an in vitro study. Indian J Dent Res. 2017;28(2):181–6. doi: 10.4103/ijdr.IJDR_34_16. [PubMed] [CrossRef] [Google Scholar]
40. Gundappa M, Bansal R, Khoriya S, Mohan R. Root canal centering ability of rotary cutting nickel titanium instruments: a meta-analysis. J Conserv Dent. 2014;17(6):504–9. doi: 10.4103/0972-0707.144567. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
41. Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root fillings. J Endod. 2000;26(4):210–6. doi: 10.1097/00004770-200004000-00003. [PubMed] [CrossRef] [Google Scholar]
42. White RR, Goldman M, Lin PS. The influence of the smeared layer upon dentinal tubule penetration by endodontic filling materials. Part II. J Endod. 1987;13(8):369–74. doi: 10.1016/S0099-2399(87)80195-4. [PubMed] [CrossRef] [Google Scholar]
43. Kennedy WA, Walker WA, III, Gough RW. Smear layer removal effects on apical leakage. J Endod. 1986;12(1):21–7. doi: 10.1016/S0099-2399(86)80277-1. [PubMed] [CrossRef] [Google Scholar]
44. Saunders WP, Saunders EM. The effect of smear layer upon the coronal leakage of gutta-percha fillings and a glass ionomer sealer. Int Endod J. 1992;25(5):245–9. doi: 10.1111/j.1365-2591.1992.tb01157.x. [PubMed] [CrossRef] [Google Scholar]
45. Kiran S, Prakash S, Siddharth PR, Saha S, Geojan NE, Ramachandran M. Comparative evaluation of smear layer and debris on the canal walls prepared with a combination of Hand and Rotary ProTaper technique using scanning Electron microscope. J Contemp Dent Pract. 2016;17(7):574–81. doi: 10.5005/jp-journals-10024-1892. [PubMed] [CrossRef] [Google Scholar]
46. Plotino G, Ozyurek T, Grande NM, Gundogar M. Influence of size and taper of basic root canal preparation on root canal cleanliness: a scanning electron microscopy study. Int Endod J. 2019;52(3):343–51. doi: 10.1111/iej.13002. [PubMed] [CrossRef] [Google Scholar]
47. Plotino G, Giansiracusa Rubini A, Grande NM, Testarelli L, Gambarini G. Cutting efficiency of Reciproc and waveOne reciprocating instruments. J Endod. 2014;40(8):1228–30. doi: 10.1016/j.joen.2014.01.041. [PubMed] [CrossRef] [Google Scholar]
48. Feghali M, Jabbour E, Koyess E, Sabbagh J. Scanning electron microscopy evaluation of debris and smear layer generated by two instruments used in reciprocating motion WaveOne Gold(R) and Reciproc Blue(R) Aust Endod J. 2019;45(3):388–93. doi: 10.1111/aej.12338. [PubMed] [CrossRef] [Google Scholar]

Articles from BMC Oral Health are provided here courtesy of BMC

  NODES
innovation 1
INTERN 4
Note 5
Project 1
twitter 2