A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
- PMID: 10416900
A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
Abstract
Oral implant treatment ad modum Brånemark was undertaken in nine patients with edentulous maxillae. Cutting torque measurements and resonance frequency analyses (RFA) were conducted at implant placement and the corresponding values were subjected to correlation analyses. The implants were also evaluated with RFA at abutment connection and at one-year follow-up in order to identify possible changes in implant stability. A total of 61 implants were inserted, of which 49 were of the Mk II self-tapping type. Two implants were lost during the study period. The cumulative torque was presented as a mean value for the upper/crestal, the middle and the lower/apical third of the implant site respectively, as well as an overall value for the whole site. The highest correlation (r = 0.84, P<0.05) was found when comparing the mean torque values of the upper/crestal portion with the resonance frequency values at implant placement. The Mk II implant sites were divided into three groups based on the values of the cutting torque, i.e. soft (group 1), medium (group 2) and dense bone (group 3). The mean value of each group was plotted against the corresponding mean value of resonance frequency measured at implant insertion. Statistical analysis showed significant differences in resonance frequency at implant insertion between groups 1 and 2 (P = 0.047) and between groups 1 and 3 (P = 0.002). When repeating the resonance frequency analyses at second stage surgery and at one-year follow-up, no significant differences were detected between any of the groups. It was shown that the stability of implants placed in softer bone seemed to "catch up" over time with more dense bone sites.
Similar articles
-
On cutting torque measurements during implant placement: a 3-year clinical prospective study.Clin Implant Dent Relat Res. 1999;1(2):75-83. doi: 10.1111/j.1708-8208.1999.tb00095.x. Clin Implant Dent Relat Res. 1999. PMID: 11359301 Clinical Trial.
-
Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study.Int J Oral Maxillofac Implants. 2011 Sep-Oct;26(5):1051-6. Int J Oral Maxillofac Implants. 2011. PMID: 22010089
-
One-step surgical placement of Brånemark implants: a prospective multicenter clinical study.Int J Oral Maxillofac Implants. 1997 Jul-Aug;12(4):454-62. Int J Oral Maxillofac Implants. 1997. PMID: 9274074 Clinical Trial.
-
Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data.Clin Implant Dent Relat Res. 2008 Dec;10(4):231-7. doi: 10.1111/j.1708-8208.2008.00084.x. Epub 2008 Apr 1. Clin Implant Dent Relat Res. 2008. PMID: 18384409
-
Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study.Int J Oral Maxillofac Surg. 1999 Aug;28(4):266-72. Int J Oral Maxillofac Surg. 1999. PMID: 10416893
Cited by
-
Immediate loading: a new implant technique with immediate loading and aesthetics: Nobel Active™.Oral Implantol (Rome). 2008 Jul;1(2):50-5. Epub 2009 Feb 1. Oral Implantol (Rome). 2008. PMID: 23285337 Free PMC article.
-
Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.Clin Oral Investig. 2007 Sep;11(3):257-65. doi: 10.1007/s00784-007-0115-2. Epub 2007 Mar 31. Clin Oral Investig. 2007. PMID: 17401588 Clinical Trial.
-
Is It Possible to Monitor Implant Stability on a Prosthetic Abutment? An In Vitro Resonance Frequency Analysis.Int J Environ Res Public Health. 2020 Jun 8;17(11):4073. doi: 10.3390/ijerph17114073. Int J Environ Res Public Health. 2020. PMID: 32521612 Free PMC article.
-
Mechanical and Biological Advantages of a Tri-Oval Implant Design.J Clin Med. 2019 Mar 28;8(4):427. doi: 10.3390/jcm8040427. J Clin Med. 2019. PMID: 30925746 Free PMC article.
-
Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants.Int J Dent. 2019 Apr 1;2019:3209872. doi: 10.1155/2019/3209872. eCollection 2019. Int J Dent. 2019. PMID: 31065267 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources