The agreement between the Heidelberg Retina Tomograph and a digital nonmydriatic retinal camera in assessing area cup-to-disc ratio
- PMID: 16384949
- DOI: 10.1167/iovs.05-0936
The agreement between the Heidelberg Retina Tomograph and a digital nonmydriatic retinal camera in assessing area cup-to-disc ratio
Abstract
Purpose: To determine the repeatability and agreement between a digital camera (monoscopic and stereoscopic images) and the Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) in determining cup-to-disc ratio. A secondary purpose was to determine the monoscopic and stereoscopic thresholds that maximize specificity and sensitivity when compared with the HRT.
Methods: Community living participants aged between 70 and 79 years had their optic discs imaged with a digital nonmydriatic retinal camera (NMRC) and the HRT. Intraclass correlation coefficients (ICCs) and 95% tolerance limits of change were used to determine repeatability characteristics of the instruments. The agreement between the HRT- and NMRC-derived area cup-to-disc ratios was assessed using weighted kappa statistics and receiver operator characteristic (ROC) curves.
Results: The agreements between the monoscopic and stereoscopic images and HRT were assessed for 1238 and 1173 eyes, respectively. The reliability measures for both NMRC techniques and HRT were almost perfect (ICC = 0.84-0.99) with narrow tolerance limits of change (9.2%-18.4%) and very small systemic biases (P < 0.05). The agreement between the HRT and both NMRC techniques was substantial, with a weighted kappa = 0.83. The HRT gave a marginally larger area cup-to-disc ratio than the monoscopic and stereoscopic images by 0.008 and 0.006, respectively (P < 0.001). The areas under the ROC curves for both NMRC techniques were 0.98, indicating excellent discriminating characteristics (P < 0.001). An area cup-to-disc ratio cutoff of > or =0.5 for the monoscopic and stereoscopic NMRC was highly specific (94.1% and 91.6%) and sensitive (87.5% and 97.2%, respectively) in determining an HRT-derived area cup-to-disc ratio >0.6.
Conclusions: The monoscopic and stereoscopic digital images showed excellent repeatability and demonstrated substantial agreement with the HRT. The results indicate that the digital NMRC could be a reliable and useful instrument for assessing area cup-to-disc ratio and screening for glaucoma-suspect eyes in the community.
Similar articles
-
Agreement in assessing glaucomatous discs in a clinical teaching setting with stereoscopic disc photographs, planimetry, and laser scanning tomography.J Glaucoma. 1999 Apr;8(2):99-104. J Glaucoma. 1999. PMID: 10209725
-
Assessment of optic disc cupping with digital fundus photographs.Am J Ophthalmol. 2005 Sep;140(3):529-31. doi: 10.1016/j.ajo.2005.03.002. Am J Ophthalmol. 2005. PMID: 16139006
-
Optic disc imaging with spectral-domain optical coherence tomography: variability and agreement study with Heidelberg retinal tomograph.Ophthalmology. 2012 Sep;119(9):1852-7. doi: 10.1016/j.ophtha.2012.02.033. Epub 2012 May 8. Ophthalmology. 2012. PMID: 22572035
-
An interrater reliability study of a new 'zonal' classification for reporting the location of retinal haemorrhages in childhood for clinical, legal and research purposes.Br J Ophthalmol. 2010 Jul;94(7):886-90. doi: 10.1136/bjo.2009.162271. Epub 2009 Oct 21. Br J Ophthalmol. 2010. PMID: 19846410 Review.
-
Heidelberg Retina Tomography analysis in optic disks with anatomic particularities.J Med Life. 2010 Oct-Dec;3(4):359-64. J Med Life. 2010. PMID: 21254731 Free PMC article. Review.
Cited by
-
The papilla as screening parameter for early diagnosis of glaucoma.Dtsch Arztebl Int. 2008 Aug;105(34-35):583-9. doi: 10.3238/arztebl.2008.0583. Epub 2008 Aug 25. Dtsch Arztebl Int. 2008. PMID: 19471619 Free PMC article.
-
Agreement in identification of glaucomatous progression between the optic disc photography and Heidelberg retina tomography in young glaucomatous patients.Int J Ophthalmol. 2014 Jun 18;7(3):474-9. doi: 10.3980/j.issn.2222-3959.2014.03.16. eCollection 2014. Int J Ophthalmol. 2014. PMID: 24967194 Free PMC article.
-
Mass Screening for Primary Open-Angle Glaucoma: Is It Really Relevant?Cureus. 2024 Sep 19;16(9):e69736. doi: 10.7759/cureus.69736. eCollection 2024 Sep. Cureus. 2024. PMID: 39429279 Free PMC article.
-
Capability of Ophthalmology Residents to Detect Glaucoma Using High-Dynamic-Range Concept versus Color Optic Disc Photography.J Ophthalmol. 2017;2017:8209270. doi: 10.1155/2017/8209270. Epub 2017 Jun 27. J Ophthalmol. 2017. PMID: 28740736 Free PMC article.
-
Spectral domain optical coherence tomography in glaucoma: qualitative and quantitative analysis of the optic nerve head and retinal nerve fiber layer (an AOS thesis).Trans Am Ophthalmol Soc. 2009 Dec;107:254-81. Trans Am Ophthalmol Soc. 2009. PMID: 20126502 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical