High-performance mass spectrometry: Fourier transform ion cyclotron resonance at 14.5 Tesla
- PMID: 18465882
- DOI: 10.1021/ac800386h
High-performance mass spectrometry: Fourier transform ion cyclotron resonance at 14.5 Tesla
Abstract
We describe the design and current performance of a 14.5 T hybrid linear quadrupole ion trap Fourier transform ion cyclotron resonance mass spectrometer. Ion masses are routinely determined at 4-fold better mass accuracy and 2-fold higher resolving power than similar 7 T systems at the same scan rate. The combination of high magnetic field and strict control of the number of trapped ions results in external calibration broadband mass accuracy typically less than 300 ppb rms, and a resolving power of 200,000 (m/Delta m50% at m/z 400) is achieved at greater than 1 mass spectrum per second. Novel ion storage optics and methodology increase the maximum number of ions that can be delivered to the FTICR cell, thereby improving dynamic range for tandem mass spectrometry and complex mixture applications.
Similar articles
-
An external source 7 T Fourier transform ion cyclotron resonance mass spectrometer with electrostatic ion guide.Rapid Commun Mass Spectrom. 1996;10(14):1845-9. doi: 10.1002/(SICI)1097-0231(199611)10:14<1845::AID-RCM749>3.0.CO;2-#. Rapid Commun Mass Spectrom. 1996. PMID: 8953787
-
A new hybrid electrospray Fourier transform mass spectrometer: design and performance characteristics.Rapid Commun Mass Spectrom. 2006;20(2):259-66. doi: 10.1002/rcm.2307. Rapid Commun Mass Spectrom. 2006. PMID: 16353130
-
Electrospray ionization Fourier transform ion cyclotron resonance at 9.4 T.Rapid Commun Mass Spectrom. 1996;10(14):1824-8. doi: 10.1002/(SICI)1097-0231(199611)10:14<1824::AID-RCM695>3.0.CO;2-E. Rapid Commun Mass Spectrom. 1996. PMID: 8953784
-
Tandem mass spectrometry in quadrupole ion trap and ion cyclotron resonance mass spectrometers.Methods Enzymol. 2005;402:109-48. doi: 10.1016/S0076-6879(05)02004-5. Methods Enzymol. 2005. PMID: 16401508 Review.
-
Fourier transform ion cyclotron resonance mass spectrometry: a primer.Mass Spectrom Rev. 1998 Jan-Feb;17(1):1-35. doi: 10.1002/(SICI)1098-2787(1998)17:1<1::AID-MAS1>3.0.CO;2-K. Mass Spectrom Rev. 1998. PMID: 9768511 Review.
Cited by
-
Automated data reduction for hydrogen/deuterium exchange experiments, enabled by high-resolution Fourier transform ion cyclotron resonance mass spectrometry.J Am Soc Mass Spectrom. 2010 Apr;21(4):550-8. doi: 10.1016/j.jasms.2009.12.016. Epub 2010 Jan 4. J Am Soc Mass Spectrom. 2010. PMID: 20116280 Free PMC article.
-
Performance evaluation of a high-field Orbitrap mass analyzer.J Am Soc Mass Spectrom. 2009 Aug;20(8):1391-6. doi: 10.1016/j.jasms.2009.01.005. Epub 2009 Jan 18. J Am Soc Mass Spectrom. 2009. PMID: 19216090
-
Twelve million resolving power on 4.7 T Fourier transform ion cyclotron resonance instrument with dynamically harmonized cell--observation of fine structure in peptide mass spectra.J Am Soc Mass Spectrom. 2014 May;25(5):790-9. doi: 10.1007/s13361-014-0846-7. Epub 2014 Mar 7. J Am Soc Mass Spectrom. 2014. PMID: 24604470
-
Identification and Characterization of Human Proteoforms by Top-Down LC-21 Tesla FT-ICR Mass Spectrometry.J Proteome Res. 2017 Feb 3;16(2):1087-1096. doi: 10.1021/acs.jproteome.6b00696. Epub 2016 Dec 12. J Proteome Res. 2017. PMID: 27936753 Free PMC article.
-
Laserspray and matrix-assisted ionization inlet coupled to high-field FT-ICR mass spectrometry for peptide and protein analysis.J Am Soc Mass Spectrom. 2013 Mar;24(3):320-8. doi: 10.1007/s13361-012-0545-1. Epub 2013 Feb 5. J Am Soc Mass Spectrom. 2013. PMID: 23381687
LinkOut - more resources
Full Text Sources
Other Literature Sources