Aortic valve replacement reduces valvuloarterial impedance but does not affect systemic arterial compliance in elderly men with degenerative calcific trileaflet aortic valve stenosis
- PMID: 25267695
- DOI: 10.1053/j.jvca.2014.05.017
Aortic valve replacement reduces valvuloarterial impedance but does not affect systemic arterial compliance in elderly men with degenerative calcific trileaflet aortic valve stenosis
Abstract
Objective: Standard methods of quantifying aortic valve stenosis (AS), which focus entirely on the valve itself, do not adequately characterize the magnitude, predict the onset, progression, and severity of symptoms, or identify the incidence of subsequent adverse events. Valvuloarterial impedance (Z(va)) is an index of global left ventricular (LV) afterload that incorporates valvular and arterial loads. The authors tested the hypothesis that aortic valve replacement (AVR) reduces Z(va) but does not affect the arterial component of LV afterload in elderly patients with degenerative calcific trileaflet AS.
Design: Observational study.
Setting: Veterans affairs medical center.
Participants: Eight elderly (age, 79 ± 4 years) men with moderate-to-severe AS and normal preoperative LV function (ejection fraction, 61% ± 9%) scheduled for AVR with or without coronary artery bypass graft surgery were studied after institutional review board approval.
Interventions: None.
Measurements and main results: A comprehensive TEE examination was performed during isoflurane-fentanyl-rocuronium anesthesia. Doppler echocardiography was used to measure pressure gradients across the aortic valve, stroke volume (continuity equation), and aortic valve area using standard techniques. Z(va) was determined as (systolic arterial pressure+mean gradient)/stroke volume index. Energy loss index was calculated as (aortic area × aortic valve area)/([aortic area--aortic valve area]× body surface area). The stroke work loss was obtained as (mean gradient × 100/[systolic arterial pressure+mean gradient]). The ratio of stroke volume index to pulse pressure was used to measure systemic arterial compliance. Z(va), energy loss index, stroke work loss, and systemic arterial compliance were assessed before and 15 minutes after cardiopulmonary bypass. Systemic and pulmonary hemodynamics (invasive catheters) were similar after versus before AVR. Aortic valve area increased significantly (p<0.05) with AVR (0.92 ± 0.26 cm(2) to 1.94 ± 0.35 cm(2)), concomitant with decreases in peak and mean gradients (60 ± 17 mmHg to 15 ± 8 mmHg and 38 ± 11 mmHg to 8 ± 5 mmHg, respectively) and peak blood flow velocity (3.9 ± 0.5 m · s(-1) to 1.9 ± 0.5 m · s(-1)). AVR reduced Z(va) (4.6 ± 1.0 mmHg · mL(-1) · m(-2) to 3.5 ± 0.3 mmHg · mL(-1) · m(-2)) and improved energy loss index (0.55 ± 0.16 cm(2) · m(-2) to 1.58 ± 0.48 cm(2) · m(-2)) concomitant with a decline in stroke work loss (25% ± 6% to 7% ± 4%), but systemic arterial compliance remained unchanged (0.63 ± 0.13 compared with 0.70 ± 0.12 mL · mmHg(-1)· m(-2)).
Conclusion: The current results showed that AVR acutely reduced Zva, improved energy loss index, and decreased stroke work loss, but did not affect systemic arterial compliance in elderly men with degenerative calcific trileaflet AS.
Keywords: aortic valve stenosis; energy loss index; hemodynamics; left ventricular afterload; systemic arterial compliance; valvuloarterial impedance.
Published by Elsevier Inc.
Similar articles
-
Chronic pressure-overload hypertrophy attenuates vortex formation time in patients with severe aortic stenosis and preserved left ventricular systolic function undergoing aortic valve replacement.J Cardiothorac Vasc Anesth. 2013 Aug;27(4):660-4. doi: 10.1053/j.jvca.2013.01.007. Epub 2013 May 30. J Cardiothorac Vasc Anesth. 2013. PMID: 23727466
-
Moderate Aortic Valvular Insufficiency Invalidates Vortex Formation Time as an Index of Left Ventricular Filling Efficiency in Patients With Severe Degenerative Calcific Aortic Stenosis Undergoing Aortic Valve Replacement.J Cardiothorac Vasc Anesth. 2016 Oct;30(5):1260-5. doi: 10.1053/j.jvca.2016.03.144. Epub 2016 Mar 23. J Cardiothorac Vasc Anesth. 2016. PMID: 27474333
-
Systemic vascular load in calcific degenerative aortic valve stenosis: insight from percutaneous valve replacement.J Am Coll Cardiol. 2015 Feb 10;65(5):423-33. doi: 10.1016/j.jacc.2014.10.067. J Am Coll Cardiol. 2015. PMID: 25660919
-
Latent myopathy is more pronounced in patients with low flow versus normal flow aortic stenosis with normal left ventricular ejection fraction who are undergoing surgical aortic valve replacement: Multicenter study with a brief review of the literature.Echocardiography. 2018 May;35(5):611-620. doi: 10.1111/echo.13839. Epub 2018 Apr 1. Echocardiography. 2018. PMID: 29605969 Review.
-
Transcatheter aortic valve implantation: anesthetic considerations.Anesth Analg. 2009 May;108(5):1453-62. doi: 10.1213/ane.0b013e31819b07ce. Anesth Analg. 2009. PMID: 19372319 Review.
Cited by
-
Dissecting myocardial mechanics in patients with severe aortic stenosis: 2-dimensional vs 3-dimensional-speckle tracking echocardiography.BMC Cardiovasc Disord. 2020 Jan 30;20(1):33. doi: 10.1186/s12872-020-01336-0. BMC Cardiovasc Disord. 2020. PMID: 32000672 Free PMC article.
-
The Role of Index of Valvular-Arterial Impedance and Systemic Arterial Compliance after Aortic Valve Replacement.J Cardiovasc Ultrasound. 2016 Sep;24(3):191-192. doi: 10.4250/jcu.2016.24.3.191. Epub 2016 Sep 26. J Cardiovasc Ultrasound. 2016. PMID: 27721945 Free PMC article. No abstract available.
-
Hypertension and transcatheter aortic valve replacement: parallel or series?Integr Blood Press Control. 2018 Nov 23;11:81-91. doi: 10.2147/IBPC.S177258. eCollection 2018. Integr Blood Press Control. 2018. PMID: 30538539 Free PMC article. Review.
Publication types
MeSH terms
Supplementary concepts
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials