Prediction of viral filtration performance of monoclonal antibodies based on biophysical properties of feed
- PMID: 25919945
- DOI: 10.1002/btpr.2094
Prediction of viral filtration performance of monoclonal antibodies based on biophysical properties of feed
Abstract
Controlling viral contamination is an important issue in the process development of monoclonal antibodies (MAbs) produced from mammalian cell lines. Virus filtration (VF) has been demonstrated to be a robust and effective clearance step which can provide ≥4 logs of reduction via size exclusion. The minimization of VF area by increasing flux and filter loading is critical to achieving cost _targets as VFs are single use and often represent up to 10% of total purification costs. The research presented in this publication describes a development strategy focused on biophysical attributes of product streams that are directly applicable to VF process performance. This article summarizes a case study where biophysical tools (high-pressure size exclusion chromatography, dynamic light scattering, and absolute size exclusion chromatography) were applied to a specific MAb program to illustrate how changes in feed composition (pH, sodium chloride concentration, and buffer salt type) can change biophysical properties which correlate with VF performance. The approach was subsequently refined and expanded over the course of development of three MAbs where performance metrics (i.e., loading and flux) were evaluated for two specific virus filters (Viresolve Pro and Planova 20N) during both unspiked control runs and virus clearance experiments. The analyses of feed attributes can be applied to a decision tree to guide the recommendation of a VF filter and operating conditions for use in future MAb program development. The understanding of the biophysical properties of the feed can be correlated to virus filter performance to significantly reduce the mass of product, time, and costs associated with virus filter step development.
Keywords: dynamic light scattering; monoclonal antibody purification; viral clearance; virus filter performance; virus removal filters.
© 2015 American Institute of Chemical Engineers.
Similar articles
-
Limits in virus filtration capability? Impact of virus quality and spike level on virus removal with xenotropic murine leukemia virus.Biotechnol Prog. 2015 Jan-Feb;31(1):135-44. doi: 10.1002/btpr.2020. Epub 2014 Nov 29. Biotechnol Prog. 2015. PMID: 25395156
-
Achieving a Successful Scale-Down Model and Optimized Economics through Parvovirus Filter Validation using Purified TrueSpikeTM Viruses.PDA J Pharm Sci Technol. 2015 May-Jun;69(3):440-9. doi: 10.5731/pdajpst.2015.01054. PDA J Pharm Sci Technol. 2015. PMID: 26048749
-
Virus filtration of high-concentration monoclonal antibody solutions.Biotechnol Prog. 2009 Mar-Apr;25(2):483-91. doi: 10.1002/btpr.177. Biotechnol Prog. 2009. PMID: 19353736
-
Use of MMV as a Single Worst-Case Model Virus in Viral Filter Validation Studies.PDA J Pharm Sci Technol. 2014 May-Jun;68(3):297-311. doi: 10.5731/pdajpst.2014.00978. PDA J Pharm Sci Technol. 2014. PMID: 25188350 Review.
-
Integration of Planova filters in manufacturing processes of biologicals improve the virus safety effectively: A review of publicly available data.Biotechnol Prog. 2024 Jan-Feb;40(1):e3398. doi: 10.1002/btpr.3398. Epub 2023 Nov 20. Biotechnol Prog. 2024. PMID: 37985214 Review.
Cited by
-
Characterizing the impact of pressure on virus filtration processes and establishing design spaces to ensure effective parvovirus removal.Biotechnol Prog. 2017 Sep;33(5):1294-1302. doi: 10.1002/btpr.2506. Epub 2017 Jun 21. Biotechnol Prog. 2017. PMID: 28556575 Free PMC article.
-
Process- and Product-Related Foulants in Virus Filtration.Bioengineering (Basel). 2022 Apr 4;9(4):155. doi: 10.3390/bioengineering9040155. Bioengineering (Basel). 2022. PMID: 35447715 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources