Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery
- PMID: 27521967
- DOI: 10.1053/j.jvca.2016.03.141
Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery
Abstract
Objective: The aim of this study was to compare deep body temperature obtained using a novel noninvasive continuous zero-heat-flux temperature measurement system with core temperatures obtained using conventional methods.
Design: A prospective, observational study.
Setting: Operating room of a university hospital.
Participants: The study comprised 15 patients undergoing vascular surgery of the lower extremities and 15 patients undergoing cardiac surgery with cardiopulmonary bypass.
Interventions: Zero-heat-flux thermometry on the forehead and standard core temperature measurements.
Measurements and main results: Body temperature was measured using a new thermometry system (SpotOn; 3M, St. Paul, MN) on the forehead and with conventional methods in the esophagus during vascular surgery (n = 15), and in the nasopharynx and pulmonary artery during cardiac surgery (n = 15). The agreement between SpotOn and the conventional methods was assessed using the Bland-Altman random-effects approach for repeated measures. The mean difference between SpotOn and the esophageal temperature during vascular surgery was+0.08°C (95% limit of agreement -0.25 to+0.40°C). During cardiac surgery, during off CPB, the mean difference between SpotOn and the pulmonary arterial temperature was -0.05°C (95% limits of agreement -0.56 to+0.47°C). Throughout cardiac surgery (on and off CPB), the mean difference between SpotOn and the nasopharyngeal temperature was -0.12°C (95% limits of agreement -0.94 to+0.71°C). Poor agreement between the SpotOn and nasopharyngeal temperatures was detected in hypothermia below approximately 32°C.
Conclusions: According to this preliminary study, the deep body temperature measured using the zero-heat-flux system was in good agreement with standard core temperatures during lower extremity vascular and cardiac surgery. However, agreement was questionable during hypothermia below 32°C.
Keywords: body temperature; core temperature; monitoring; noninvasive; thermometer; zero-heat-flux.
Copyright © 2016 Elsevier Inc. All rights reserved.
Similar articles
-
Intraoperative temperature monitoring with zero heat flux technology (3M SpotOn sensor) in comparison with sublingual and nasopharyngeal temperature: An observational study.Eur J Anaesthesiol. 2015 Jun;32(6):387-91. doi: 10.1097/EJA.0000000000000232. Eur J Anaesthesiol. 2015. PMID: 25693138 Clinical Trial.
-
Intra-operative temperature monitoring with cutaneous zero-heat- flux-thermometry in comparison with oesophageal temperature: A prospective study in the paediatric population.Paediatr Anaesth. 2019 Aug;29(8):865-871. doi: 10.1111/pan.13653. Epub 2019 May 27. Paediatr Anaesth. 2019. PMID: 31034706 Clinical Trial.
-
Rectal and Bladder Temperatures vs Forehead Core Temperatures Measured With SpotOn Monitoring System.Am J Crit Care. 2018 Jan;27(1):43-50. doi: 10.4037/ajcc2018865. Am J Crit Care. 2018. PMID: 29292274 Clinical Trial.
-
Accuracy and precision of zero-heat-flux temperature measurements with the 3M™ Bair Hugger™ Temperature Monitoring System: a systematic review and meta-analysis.J Clin Monit Comput. 2021 Feb;35(1):39-49. doi: 10.1007/s10877-020-00543-6. Epub 2020 Jun 2. J Clin Monit Comput. 2021. PMID: 32488679 Review.
-
Agreement of infrared temporal artery thermometry with other thermometry methods in adults: systematic review.J Clin Nurs. 2016 Apr;25(7-8):894-905. doi: 10.1111/jocn.13117. Epub 2016 Jan 27. J Clin Nurs. 2016. PMID: 26994990 Review.
Cited by
-
Determining the accuracy of zero-flux and ingestible thermometers in the peri-operative setting.J Clin Monit Comput. 2019 Dec;33(6):1113-1118. doi: 10.1007/s10877-019-00252-9. Epub 2019 Jan 8. J Clin Monit Comput. 2019. PMID: 30623279
-
Comparison of zero heat flux and double sensor thermometers during spinal anaesthesia: a prospective observational study.J Clin Monit Comput. 2022 Oct;36(5):1547-1555. doi: 10.1007/s10877-021-00799-6. Epub 2022 Jan 3. J Clin Monit Comput. 2022. PMID: 34978656 Free PMC article.
-
Toward Non-Invasive Core Body Temperature Sensing.Proc (USNC URSI Radio Sci Meet). 2021 Jan;2021:164-165. doi: 10.23919/usnc-ursinrsm51531.2021.9336477. Epub 2021 Feb 3. Proc (USNC URSI Radio Sci Meet). 2021. PMID: 33693311 Free PMC article.
-
In response to: "Temperature monitoring with zero-heat-flux technology in neurosurgical patients".J Clin Monit Comput. 2019 Oct;33(5):931-932. doi: 10.1007/s10877-019-00275-2. Epub 2019 Feb 15. J Clin Monit Comput. 2019. PMID: 30771199 No abstract available.
-
Evaluation of the novel non-invasive zero-heat-flux Tcore™ thermometer in cardiac surgical patients.J Clin Monit Comput. 2019 Feb;33(1):165-172. doi: 10.1007/s10877-018-0143-2. Epub 2018 Apr 17. J Clin Monit Comput. 2019. PMID: 29667096
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical